Datasheet

1/32 DIN Digital Panel Meter K3GN K-21
Panel
indicators
Levels
“Level” refers to a grouping of parameters. The following table lists the operations that are possible in each of the levels, and how to move between
levels. There are some parameters that are not displayed for certain models.
Note: The move to protection level time can be set in the advanced function setting level.
Level name Function Measurement
Protect Setting lockouts. Continue
Operation Displaying process values, setting/clearing forced-zero function, and
setting OUT 1/2 set values.
Continue
Adjustment Setting communications writing control. Continue
Initial setting Making initial settings of input type, scaling, output operating action,
and other parameters.
Stopped
Communications setting Setting baud rate, word length, and other communications data. Stopped
Advanced function setting Setting average processing, display color settings, and other ad-
vanced function parameters.
Stopped
Calibration Setting user calibration of the inputs. Stopped
+
+
-1234.5
Protection
Operation
Adjustment
Power ON
1 s min.
1 s min.
Initial setting
Password "0169"
1 s min.
Calibration
Password "1201"
Continue to press the key for 2 s min.
Indicates change of level.
1 s min.
Less than 1 s
Less than 1 s
(see note)
Time set
by user
Flashing stops if key
is released.
Communications
setting
Advanced function
setting