Datasheet

2
HL-5000
Characteristics
Note: 1. The above figures are initial values.
2. The above characteristics may vary depending on the model. For
further details, contact your OMRON sales representative.
* The values are calculated at an operating temperature of +5
°C to +35°C, and
an operating humidity of 40% to 70%RH. Contact your OMRON sales
representative for more detailed information on other operating environments.
Engineering Data
Electrical Durability (cos dia. =1)
(Operating temperature: +5°C to +35°C,
Operating humidity: 40% to 70%RH)
Structure and Nomenclature
Structure Contact Form
Degree of protection IP65
Durability
*
Mechanical
10,000,000 operations min. (under
rated conditions)
Electrical See the following Electrical Durability.
Operating speed 5 mm/s to 0.5 m/s
Operating
frequency
Mechanical 120 operations/min
Electrical 30 operations/min
Insulation resistance 100 MΩ min. (at 500 VDC)
Contact resistance 25 mΩ max. (initial value)
Dielectric strength
1,000 VAC, 50/60 Hz for 1 min between
terminals of the same polarity
1,500 VAC, 50/60 Hz for 1 min between
current-carrying metal parts and ground
1,500 VAC, 50/60 Hz for 1 min between
each terminal and non-current-carrying
metal part
Rated frequency 50/60 Hz
Vibration
resistance
Malfunction 10 to 55 Hz, 1.5-mm double amplitude
Shock
resistance
Destruction 1,000 m/s
2
max.
Malfunction 300 m/s
2
max.
Ambient operating
temperature
5°C to +65°C (with no icing)
Ambient operating
humidity
35% to 95%RH
Weight Approx. 130 to 190 g
1,000
500
0
12 34 56
Switching current (A)
Operating frequency:
30 operations/min
125 VAC (cos dia. = 1)
Durability (x 10
4
operations)
Cover
Resin roller
Lever
Head
Built-in switch
Connector
3 (NO)
2 (NC)
(NO) 4
(NC) 1
Za