Datasheet

HL-5000
HL-5000
7
Others
Do not use the Limit Switch outdoors, otherwise the Limit Switch
will become damaged by rust or ozone.
The Limit Switch is not suitable in places exposed to the spray of
rainwater, seawater, or oily water. Consult your OMRON
representative for models resisting rainwater, seawater, and oily
water.
If high-sealing performance is required along with shielded
wiring or conduit wiring, use the D4C or WL.
Correct Tightening Torque
A loose screw may result in a malfunction. Be sure to tighten each
screw to the proper tightening torque as shown below.
No.
Type Optimum tightening
torque
1 Head mounting screw
0.49 to 0.59 N S m
2 Cover mounting screw
0.49 to 0.59 N S m
3 Allen-head bolt
4.90 to 5.88 N S m
4 Terminal screw
0.49 to 0.59 N S m
5 Switch mounting screw
4.90 to 5.88 N S m
Note: If the head direction has been changed, check the torque of
each screw and make sure that the screws are free of for-
eign substances, and that each screw is tightened to the
proper torque.
1
2
3
4
5
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. C004-E1-9