Datasheet
HL-5000
HL-5000
3
Operating Characteristics
Model
HL-5000 HL-5030
(see note)
HL-5050
(see note)
HL-5100 HL-5200 HL-5300 HL-5500
OF max. 7.35 N 7.35 N 7.35 N 8.83 N 8.83 N 1.47 N 19.61 N
RF min. 0.98 N 0.98 N 0.98 N 1.47 N 1.47 N --- 1.96 N
PT max. 20° 20° 20° 1.5 mm 1.5 mm 30 mm 1.5 mm
OT min. 50° 50° 50° 4 mm 4 mm --- 4.5 mm
MD max. 12° 12° 12° 1 mm 1 mm --- 0.7 mm
OP --- 30±0.8 mm 40±0.8 mm --- ---
Note: 1. Measured with the types of the 31.5-mm arm or rod length.
2. OF and RF measured at the arm length of 75 mm for HL-5030, and 145 mm for HL-5050 (reference values).
Model
HL-5030 HL-5050
OF 3.09 N 1.60 N
RF 0.41 N 0.22 N
Engineering Data
Reference Data
Electrical Life Expectancy (cosφ=1)
Life expectancy (x 10 operations)
4
Switching current (A)
Operating frequency:
30 operations/min
125 VAC (cosφ = 1)
Operating temperature: 5°C to 30°C
Operating humidity: 40% to 70%