Datasheet

Multifunction Preset Counter H7CX-A 7
Life-test Curve (Reference Values)
Resistive Load Inductive Load
Reference: A current of 0.15 A max. can be switched at 125 VDC (cosφ=1) and current of 0.1 A max. can be switched if L/R=7 ms. In both cases,
a life of 100,000 operations can be expected.
The minimum applicable load is 10 mA at 5 VDC (failure level: P).
Inrush Current (Reference Values)
1,000
700
500
300
100
70
50
01 2 3
4
250 VAC (cosφ=1)
Load current (A)
30 VDC (cosφ=1)
No. of operations (×10
3
)
1,000
700
500
300
100
70
50
01 2 3
4
250 VAC cosφ=0.4
Load current (A)
30 VDC (L/R=7 ms)
No. of operations (×10
3
)
Model Voltage Applied voltage Inrush current (peak value) Time
H7CX-A11/-AW 100 to 240 VAC 264 VAC 5.8 A 0.7 ms
H7CX-A11D1/-AWD1 24 VAC/12 to 24 VDC 26.4 VAC 10.4 A 1.2 ms
H7CX-AD 12 to 24 VDC 26.4 VDC 6.0 A 1.2 ms