Tachometer H7CX-R 47
Input Connections
The inputs of the H7CX-R can be used as either no-voltage (short-circuit or open) inputs or voltage inputs. They are set for use as voltage inputs
at the time of delivery.
No-voltage Inputs (NPN Inputs)
No-voltage Input Signal Levels
Note: The DC voltage must be 30 VDC max.
Applicable Two-wire Sensor
Leakage current: 1.5 mA max.
Switching capacity: 5 mA min.
Residual voltage: 3.0 VDC max.
Operating voltage: 10 VDC
Voltage Inputs (PNP Inputs)
Voltage Input Signal Levels
High level (Input ON): 4.5 to 30 VDC
Low level (Input OFF): 0 to 2 VDC
Input resistance: Approx. 4.7 k
Note: The DC voltage must be 30 VDC max.
0 V
0 V
0 V
0 V
3 54 7 6
3 654 7
3 654 7
3 6547
Open Collector
Operates when the transistor turns ON.
Voltage Output
Operates when the transistor turns ON.
Contact Input
Operates when the contact turns ON.
PLC or
sensor
Operates when the transistor turns ON.
DC Two-wire Sensor
Sensor
Input
Hold
Count
Input
Hold
Count
Input
Hold
Count
Input
Hold
Count
Terminal
number
Terminal
number
Terminal
number
Terminal
number
No-contact input Short-circuit level (Transistor ON)
Residual voltage: 3 V max.
Impedance when ON: 1 k
max.
(The leakage current is 5 to 20 mA when the
impedance is 0
.)
Open level (Transistor OFF)
Impedance when OFF: 100 k
min.
Contact input Use contact which can adequately switch
5 mA at 10 V.
0 V
0 V
0 V
3 654 7
3 654 7
3 6547
Sensor
Operates when the transistor turns OFF. Operates when the transistor turns ON.
Contact Input
Operates when the contact turns ON.
Input
Hold
Count
No-contact Input
(NPN Transistor)
No-contact Input
(PNP Transistor)
Sensor
Input
Hold
Count
Input
Hold
Count
Terminal
number
Terminal
number
Terminal
number