Datasheet
Multifunction Preset Counter H7CX-A 17
Operating Procedures
■ Setting Procedure Guide
Setting for Counter Operation
(1-stage/2-stage Counter, Total and Preset Counter, Batch Counter, Dual Counter)
Note: 1. At the time of delivery, the H7CX is set to the 1-stage counter (2-stage counter for H7CX-AW@/-A4W@ models) configuration.
2. Set to output 2 time when using as a 2-stage counter or batch counter.
Setting for Tachometer Operation
Note: At the time of delivery, the H7CX is set to the 2-stage counter (1-stage counter for H7CX-AU@ models) configuration.
12345678
➡
➡
➡
OFF
ON
When Using Basic Settings Only
When Using Settings Other than the Above When Using Advanced Functions
Other Settings Advanced Functions
• Counting speed (30 Hz, 5 kHz)
• Input mode (UP, DOWN)
• Output mode (N, F, C, K-1)
• One-shot output time (0.5 s, 0.05 s)(See note 2.)
• Reset input signal width (20 ms, 1 ms)
• NPN/PNP input mode (NPN, PNP)
Basic Settings
The settings can be performed easily with the DIP switch.
For details on the setting methods, refer to page 18.
All the functions can be set with the operation keys.
For details on the setting methods, refer to page 19.
• Input mode (UP/DOWN A, UP/DOWN B, UP/DOWN C)
• Output mode (R, P, Q, A, K-2, D, L, H)
• One-shot output time (except for 0.5 s and 0.05 s) (See note 2.)
Settings for advanced functions other than the basic
settings above can be performed with the operation keys.
For details on the setting methods, refer to page 19.
• Dual count calculating mode
• Output 1 time (for 2-stage counter)
• Decimal point position
• Prescale value
• Display color
• Output allocation
• Key protect level
12345678
➡
➡
OFF
ON
When Using Basic Settings Only
When Using Advanced Functions
Advanced Functions
• Counting speed (30 Hz, 10 kHz)
• Output mode (HI-LO, AREA, HI-HI, LO-LO)
• Average processing (OFF, 2, 4, 8 times)
• NPN/PNP input mode (NPN, PNP)
Basic Settings
The settings can be performed easily with the DIP switch.
For details on the setting methods, refer to page 30.
Settings for advanced functions other than the basic
settings above can be performed with the operation keys.
For details on the setting methods, refer to page 31.
• Decimal point position
• Prescale value
• Auto-zero time
• Startup time
• Display color
• Output allocation
• Key protect level