H5CX-B@-N
37
Operating Procedures
DIP Switch Settings
All functions are set using the DIP switch.
Operation in Run Mode
Forecast Value Setting Absolute Value Setting
Note: 1. All the pins are factory-set to OFF.
2. DIP switch settings are effective when the power is
turned ON again. (Set the DIP switch before installation
and power-up.)
Item OFF ON
1
Time range
Refer to the table on the
right.
2
3 Output modes F-1 mode
A mode
4 Input signal width 20 ms 1 ms
5 NPN/PNP input mode
NPN
(no-voltage)
PNP
(voltage)
6 Reset Key protection Disabled Enabled
7 Up Key protection Disabled Enabled
8 Mode Key protection Disabled Enabled
Pin 1 Pin 2 Time range
OFF OFF 0.1 h to 99999.9 h
ON OFF 0.01 s to 9999.99 s
OFF ON
0 h 00 min 01 s to
99 h 59 min 59 s
ON ON 0.1 min to 99999.9 min
OFF
ON
12345678
Set the digits for the set values using the corresponding Key.
Set value
Present value
Forecast set value
Present value
Each time the Key is pressed,
the sub-display will switch between
the set value (“SET” is lit) and the
forecast set value (“1” is lit).
Set value 1
Present value
Set value 2
Present value
Each time the Key is pressed,
the sub-display will switch between
set value 1 (“SET 1” is lit) and set
value 2 (“SET 2” is lit).