Datasheet
H5CX-B@-N
36
Nomenclature
Key Protect Level
When the Key-protect Switch is ON, key operations are prohibited 
according to the settings for DIP switch pins 6 to 8, thus preventing 
setting errors. 
The Key-protect Switch can be turned ON and OFF while the power 
is ON. 
The Key Protection Indicator is lit orange when the Key-protect Switch 
is ON.
If the key protect switch is ON, you will not be able to switch to 
Function Setting Mode. 
Dimensions (unit: mm)
Digital Timers
Accessories (Order Separately)
Refer to page 12 for details.
OFF
(Disabled)
ON
(Enabled)
(Default setting)
11
12
10mm
6mm
1
2
3
8
9
4
6
7
5
10
Display Section
3. Reset Indicator 
(orange)
1.  Key Protection Indicator 
(orange)
2.  Control Output Indicator 
(orange)
4.  Present Value Display 
(red)
Character height: 10 mm
7.  Set Value 1, 2 Indicator 
(green)
If the time range is 0.0 min or 0.0 h, the decimal 
point flashes to indicate timing operation. 
6. Set Value 
(green)
Character height: 6 mm 
5.  Time Unit Indicators 
(green)
Lit when the reset input or Reset Key is ON.
Lit when the reset input or Reset Key is ON.
Forecast value setting
Operation Key
8. Mode Key
9. Reset Key
Switches
11. Key-protect Switch
12. DIP Switch 
First digitSixth digit
Absolute value setting
  (Changes modes and setting items)
Resets present value and output. 
Character Size 
for Present 
Value Display
Character Size 
for Set Value 
Display
 Forecast output ON: OUT 1 is lit.
 Control output ON: OUT 2 is lit.
 Control output 1 ON: OUT 1 is lit.
 Control output 2 ON: OUT 2 is lit. 
10. Up Keys 1 to 6
OFF
ON
12345678
Digital Timers
H5CX-BWSD-N (Flush Mounting Models)
44.8×44.8
59
6
48×48
Note: M3.5 terminal screw (effective length: 6 mm)
Panel Cutouts
Panel cutouts areas shown below. (according 
to DIN43700)
Note: 1. The mounting panel thickness should 
be 1 to 5 mm.
2. To allow easier operation, it is 
recommended that Adapters be 
mounted so that the gap between 
sides with hooks is at least 15 mm 
(i.e., with the panel cutouts separated 
by at least 60 mm).
3. It is possible to mount Timers side by 
side, but only in the direction without 
the hooks. However, if Timers are 
mounted side by side, water 
resistance will be lost.
60 min.
60 min.
45
+0.6
–0
45
+0.6
–0
15 min.
n side by side mounting
A
A= (48n–2.5)
+1
 –0
With Y92A-48F1 attached.
A={48n–2.5+(n–1)×4}
+1
 –0
With Y92A-48 attached.
A= (51n–5.5)
+1
 –0
Dimensions with Flush Mounting Adapter
H5CX-BWSD-N (Provided with Adapter and Waterproof Packing)
58
48
7.5 57.5
(51)
Y92F-30 (provided) 
Flush Mounting Adapter
PanelY92S-29 (provided) 
Waterproof Packing