H5CX Digital Timers with 6-digit Display, 2-stage Setting,
and Forecast Output (DIN 48 x 48-mm)
Times the daily operating hours of machinery and tools,
predicting and notifying when maintenance is required.
Easy-to-read backlit negative LCD with 6 digits (displays
to 99999.9 h).
The 2-stage settings and forecast output are ideal for
maintenance applications.
Specifications
Ratings
*1. Inrush current will flow for a short time when the power supply is turned ON.
Inrush Current (Reference Values)
*2. The display is lit only when the power is ON.
Digital Timer H5CX-B@-N
Classification Digital Timer with 6-digit display, 2-stage setting, and forecast output
Ratings
Power supply voltage 12 to 24 VDC
Operating voltage
fluctuation range
90% to 110% rated supply voltage
Power consumption Approx. 2.3 W
*1
Mounting method Flush mounting
External connections Screw terminals
Degree of protection IEC IP66, UL508 Type 4X (indoors) for panel front surface only and only when Y92S-29 Waterproof Packing is used
Digits 6 digits
Time range 0.01 s to 9999.99 s, 1 s to 99 h 59 min 59 s, 0.1 min to 99999.9 min, 0.1 h to 99999.9 h
Timer mode Elapsed time (Up)
Inputs
Input signals Signal, reset, gate
Input method
No-voltage Input ON impedance : 1 kΩ max. (Leakage current: 12 mA when 0 Ω)
ON residual voltage : 3 V max.
OFF impedance : 100 kΩ min.
Voltage Input High (logic) level : 4.5 to 30 VDC
Low (logic) level : 0 to 2 VDC (Input resistance: approx. 4.7 kΩ)
No-voltage (NPN) input/voltage (PNP) input (switchable)
Signal, reset, gate Minimum input signal width: 1 or 20 ms (selectable, same for all input)
Reset system Power resets (only for A mode), external and manual reset
Power reset Minimum power-opening time: 0.5 s (except for F-1 mode)
Reset voltage 10% max. of rated supply voltage
Sensor waiting time 250 ms max. (Control output is turned OFF and no input is accepted during sensor waiting time.)
Outputs
Output modes A, F-1
Output type
Transistor output: NPN open collector, 100 mA at 30 VDC max. residual voltage: 1.5 VDC max. (Approx. 1 V)
Leakage current: 0.1 mA max.
Display
7-segment, negative transmissive LCD;
Present value: 10-mm-high characters, red
Set value: 6-mm-high characters, green
*2
Memory backup EEPROM (overwrites: 100,000 times min.) that can store data for 10 years min.
Operating temperature range -10 to 55°C (-10 to 50°C if counters are mounted side by side) (with no icing or condensation)
Storage temperature range -25 to 70°C (with no icing or condensation)
Operating humidity range 25 to 85%
Case color Black (N1.5)
Attachments Waterproof packing, flush mounting adapter, unit label
Voltage Applied voltage Inrush current (peak value) Time
12 to 24 VDC 26.4 VDC 4.4 A 1.7 ms