Datasheet
H3DS-@LC
34
■ Wiring
Use wires of the applicable sizes specified above. The length of the exposed conductor should be 6 to 7 mm.
Use the following wiring procedure.
1. Insert the specified screwdriver into the release hole located beside the wire connection hole where the wire is to be inserted.
2. Insert the exposed conductor into the wire connection hole.
3. Pull out the screwdriver.
6 to 7 mm
Fig. 1 Exposed Conductor Length
A
A
Wire
connection
holes
Release
holes
Fig. 2 Wire Connection Holes and Release Holes
Wire connection hole
Fig. 3 Section A-A of Fig. 2
Release hole
Screwdriver
Insert
Insert
Insert
Pull out