Datasheet
B-26 Solid-state Twin Timer H3DS-F
Connections 
■ Block Diagram
■ I/O Function
■ Terminal Arrangement
Note: 1. If voltage is applied to terminal B1, or if terminals A1 and B1 are shorted, the operating mode is switched to flicker-ON start mode. If these
terminals are disconnected, the mode switches to flicker-OFF start mode.
2. DC supply voltage does not require the designation of polarity.
AC (DC) 
input
ON 
indicator 
(Orange)
OFF 
indicator 
(Green)
ON/OFF start 
selector
Indicator 
circuit
One-chip microcomputer
ROM RAM Clock
Time scale 
selector
Output 
circuit
Power 
supply 
circuit
Inputs Flicker-ON start operation begins when inputs are turned ON.
Outputs Control output Outputs are turned ON/OFF according to the time set by the ON-and OFF-time setting dial.
A1 15
15
18
18
16
16 A2
18 16 A2
15
L
18 16
B1
A1 15 B1
H3DS-FLC H3DS-FL