New Product News Solid-state Timers H3DK DIN Track-mounted, 22.5-mm-width Standard Timer Series LR • A wide AC/DC power supply range (24 to 240 VAC/DC).*1 • All sub-series include models with 12-VDC power supply.*1 • G-type Models (H3DK-G) now include model with 240 to 440VAC power supply. • UL*3, CSA, and CCC*2 certification and EN 61812-1 compliance. CE Marking. • EMC (EN 61812-1) compliance for application in heavy industrial, residential, commercial, or light industrial environments.
New Product News Multi-range, Multi-mode Timer H3DK-M/H3DK-S LR • Multiple time ranges and operating modes let you cover a wide range of applications. • The time-limit DPDT output contacts can be changed to time-limit SPDT and instantaneous SPDT output contacts using a switch. • Sequence checks are easily performed by setting an instantaneous output to 0. • Start signal control for the H3DK-M.
H3DK-M/H3DK-S Specifications ■ Time Ranges Time range setting Set time range 0.1 s 1s 10 s 1 min 10 min 1h 10 h 100 h 0.1 to 1.2 s 1 to 12 s 10 to 120 s 1 to 12 min 10 to 120 min 1 to 12 h 10 to 120 h 100 to 1,200 h Scale numbers 12 ■ Ratings Power supply voltage *1 • 24 to 240 VAC/DC, 50/60 Hz *2 • 12 VDC *2 Allowable voltage fluctuation range • 24 to 240 VAC/DC: 85% to 110% of rated voltage • 12 VDC: 90% to 110% of rated voltage Power reset Minimum power-OFF time: 0.
H3DK-M/H3DK-S ■ Characteristics ● Installation Pitch and Output Switching Capacity (Reference Values) Setting error ±10% of FS ±0.05 s max.* Minimum input signal width 50 ms* (start input) Influence of voltage ±0.5% of FS max. (±0.5% ±10 ms max. at 1.2-s range) Influence of temperature ±2% of FS max. (±2% ±10 ms max. at 1.2-s range) Insulation resistance 100 MΩ min.
H3DK-M/H3DK-S Connections ■Block Diagrams H3DK-M1/-M2 Time setting detection circuit AC (DC) input ROM Time specification switches RAM Operating mode switch Clock Power supply circuit Output circuit One-chip microcomputer Input circuit Start input Indicator circuit Power indicator Output indicator H3DK-S1/-S2 AC (DC) input Time specification switches Time setting detection circuit ROM RAM Power supply circuit Operating mode switch Clock Output circuit One-chip microcomputer Indicato
H3DK-M/H3DK-S ■ Terminal Arrangement H3DK-M1 A1 H3DK-M2 15 A1 15 H3DK-S1 25/21 A1 H3DK-S2 15 A1 15 25/21 * * R1 R1 R2 R1 R1 R2 15 15 25/21 15 15 25/21 18 16 18 B1 18 16 16 28/24 26/22 28/24 26/22 Start 18 A2 16 B1 18 16 18 28/24 26/22 Start 18 A2 See note 3. 16 18 A2 See note 3. A1 B1 (DIN notation) 15 A1 B1 15 A1 A2 A2 A2 16 18 A2 See note 3. (DIN notation) (21) 25 16 See note 3.
H3DK-M/H3DK-S Nomenclature H3DK-M2 H3DK-S2 Front View Bottom View User label attachment location Terminal Block (See notes 1 and 2.) Time range switch Output indicator (orange) (Lit while Timer gives output.) Main dial (for setting the time) Note 1. Use solid wire (2.5 mm2 max.) or ferrules with insulative sleeves to connect to the terminals. To maintain the withstand voltage after connecting the terminals, insert no more than 8 mm of exposed conductor into the terminal. Using Solid Wire (2.5 mm2 Max.
H3DK-M/H3DK-S Dimensions (Unit: mm) ■ Timers H3DK-M H3DK-S 100 88.2 22.5 22.5 22.5 69.1 4 79 65.6 52 H3DK-M2 H3DK-S2 89.4 H3DK-M1 H3DK-S1 H3DK-M2 H3DK-S2 H3DK-M1 H3DK-S1 ■ Track Mounting Products (Sold Separately) Refer to page 28 for details. Operating Procedures ■ Basic Operation ● Setting Switches • Each switch has a snap mechanism that secures the switch at given positions. Set the switch to one of these positions. Do not set it midway between two positions.
H3DK-M/H3DK-S ■ Timing Charts • There is no start input with the H3DK-S. Timer operation starts when the power is turned ON. • There is no instantaneous output with the H3DK-@1.
H3DK-M/H3DK-S D: Signal OFF delay t−a t t−a t−a t Basic Operation Power (A1 and A2) Start (B1 and A1) Power Time-limit contacts: NC 15 and 16 (25 and 26) Time-limit contacts: NO (output indicator) 15 and 18 (25 and 28) * Start input Timing Output Instantaneous contacts: NC (21 and 22) * The start input is valid while the Timer is in operation.
New Product News Twin Timer H3DK-F LR • Switch between flicker-OFF or flicker-ON start mode. • Independent ON time and OFF time settings. • Eight time ranges from 0.1 s to 1,200 h. Ordering Information ■ List of Models Operating modes Flicker OFF start/flicker ON start Supply voltage Control output H3DK-F 24 to 240 VAC/DC Contact output: SPDT Model H3DK-F 12 VDC Contact output: SPDT Model H3DK-FA ■ Accessories (Order Separately) Item Specification Model 50 cm (l) x 7.
H3DK-F *1. When using a 24-VDC power supply voltage, there will be an inrush current of approximately 0.25 A. Allow for this inrush current when turning ON and OFF the power supply to the Timer with device with a solid-state output, such as a sensor. *2. DC ripple: 20% max. *3. Refer to DC Power Consumptions (Reference Information) on page 27 for DC power consumptions. *4. The control output ratings are for one H3DK operating alone.
H3DK-F Connections ■ Block Diagrams ■ Terminal Arrangement H3DK-F H3DK-F A1 ON OFF indicator indicator ON/OFF time setting detection circuit ON/OFF start switch 15 R1 15 AC (DC) input Time specification switches Indicator circuit 18 ROM RAM 16 Clock One-chip microcomputer Power supply circuit Output circuit 18 16 A2 (DIN notation) A1 A2 15 16 18 Note: The power supply terminals do not have polarity. Nomenclature H3DK-F Front View Bottom View Note 1. Use solid wire (2.5 mm2 max.
H3DK-F Dimensions (Unit: mm) ■ Timers H3DK-F 100 88.2 22.5 69.1 4 79 65.6 52 89.4 ■ Track Mounting Products (Sold Separately) Refer to page 28 for details. Operating Procedures ■ Basic Operation Setting the Time Ranges Setting the ON/OFF Start Switch Setting the Times ● Setting the Time Ranges ● Setting an ON Start or OFF Start ● Setting the Times Use the ON time range switch to set the ON time range and the OFF time range switch to set the OFF time range.
New Product News Star-delta Timer H3DK-G LR • Set two time ranges between 1 and 120 s with one Timer. • Models with 240 to 440-VAC power supply added to series. Ordering Information ■ List of Models Operating modes Supply voltage Control output H3DK-G 24 to 240 VAC/DC Star-delta Timer Model H3DK-G Contact outputs Model Delta circuit: SPDT, Star circuit: SPDT Model 12 VDC 240 to 440 VAC H3DK-GA H3DK-GE ■ Accessories (Order Separately) Item Specification Model 50 cm (l) x 7.
H3DK-G *1. When using a 24-VDC power supply voltage, there will be an inrush current of approximately 0.25 A. Allow for this inrush current when turning ON and OFF the power supply to the Timer with device with a solid-state output, such as a sensor. *2. DC ripple: 20% max. *3. Refer to DC Power Consumptions (Reference Information) on page 27 for DC power consumptions. *4. The control output ratings are for one H3DK operating alone.
H3DK-G ■ Applicable standards Safety standards cURus: UL 508/CSA C22.2 No. 14 *1 EN 50274: Finger protection, back-of-hand proof EN 61812-1: Pollution degree 2, Overvoltage category III *2 CCC: Pollution degree 2, Overvoltage category II, section DB14048.5-2008 part 5-1 LR: Test Specification No. 1-2002 Category ENV 1.
H3DK-G Nomenclature H3DK-G Front View Bottom View Note 1. Use solid wire (2.5 mm2 max.) or ferrules with insulative sleeves to connect to the terminals. To maintain the withstand voltage after connecting the terminals, insert no more than 8 mm of exposed conductor into the terminal. User label attachment location Terminal block (See notes 1 and 2.) Star operation indicator (green) Main dial (Sets the star time.) Using Solid Wire (2.5 mm2 Max.
H3DK-G Dimensions (Unit: mm) ■ Timers H3DK-G 100 88.2 22.5 69.1 4 79 65.6 52 89.4 H3DK-GE 102 88.2 26 22.5 69.1 89.4 79 65.6 55 4 ■ Track Mounting Products (Sold Separately) Refer to page 28 for details.
H3DK-G Operating Procedures ■ Basic Operation Setting the Time Ranges Setting the Time ● Setting the Delta Time Range and the Star-delta Transfer Time (t2) ● Setting the Time The start time is set with the main dial. Star Time (t1) Range Set the star-delta transfer time. For ×1 (1 to 12 s), use side (A) (labeled “t1×1”). For ×10 (10 to 120 s), use side (B) (labeled “t10×1”). (See following diagram.) (A) Star-delta transfer time setting (t2) Switches the start time (t1) range. (B) 0.5s 0.25s 0.1s 0.
New Product News Power OFF-delay Timer H3DK-H • Set two time ranges with each Timer, from 0.1 to 12 seconds for the S Series and from 1.0 to 120 seconds for the L Series. Ordering Information ■ List of Models H3DK-H Operating modes Power OFF Delay Supply voltage S Series (time range: 0.1 to 12 s) Control output L Series (time range: 1.
H3DK-H *1. DC ripple: 20% max. (A single-phase, full-wave rectifying power supply can be connected.) *2. Refer to DC Power Consumptions (Reference Information) on page 27 for DC power consumptions. *3. The control output ratings are for one H3DK operating alone. If you operate two or more Timers side by side, refer to Installation Pitch and Output Switching Capacity (Reference Values) on the next page. ■ Characteristics Setting error ±10% of FS ±0.05 s max. Influence of voltage ±0.5% of FS max. (±0.
H3DK-H Connections ■ Block Diagrams ■ Terminal Arrangement H3DK-H H3DK-H A1 AC (DC) input Indicator circuit 15 Time specification switches R1 15 Power supply circuit Oscillation circuit Counting circuit Output circuit Power interruption detection circuit 18 18 16 16 A2 (DIN notation) A1 A2 15 16 18 Note 1: The above figure shows the terminal arrangement for a 24 to 48-VAC/DC model. Models with 100 to 120-VAC or 200 to 240-VAC power input do not have a DC input.
H3DK-H Dimensions (Unit: mm) ■ Timers H3DK-H 100 88.2 22.5 69.1 4 79 65.6 52 89.4 ■ Track Mounting Products (Sold Separately) Refer to page 28 for details. Operating Procedures ■ Basic Operation Setting the Time Ranges Setting the Time ● Setting the Time Ranges ● Setting the Time The scale multiplier can be changed with the timer range switch. It can be changed between ×0.1 s and ×1 s for an S-series Timer and between ×1 s and ×10 s for an L-series Timer.
H3DK Safety Precautions ● Refer to Safety Precautions for All Timers. Note: The following is common for all H3DK models. Caution Switching arcs or relay heating may cause fire or explosion. Do not use the Timer in the presence of inflammable or explosive gases. The H3DK Series uses a transformerless power supply system. An electrical shock may occur if an input terminal is touched while power is being supplied.
H3DK Precautions for Correct Use ● Changing Switch Settings Do not change the time unit, time scale, operating mode, or INIT/ TIME switch while the Timer is in operation. Doing so may result in malfunction. Turn OFF the power supply before changing the setting of any switch. ● Mounting and Dismounting • Although there are no particular mounting restrictions, the Timer should be mounted as horizontally as possible.
H3DK ● Wiring The H3DK-H acts like a high-impedance circuit. Therefore, the Timer may not reset if it is influenced by inductive voltage. To eliminate inductive voltage, the wires connected to the Timer must be as short as possible and should not be installed parallel to power lines. If the Timer is influenced by inductive voltage that is 30% or more of the rated voltage, connect a CR filter with a capacitance of approximately 0.
H3DK Track Mounting Products (Sold Separately) DIN Track PFP-100N PFP-50N (Unit: mm) 7.3±0.15 4.5 35±0.3 15 25 10 25 25 1,000 (500)* 10 25 27±0.15 15 (5)* 1 *Dimensions in parentheses are for the PFP-50N. DIN Track PFP-100N2 16 4.5 35±0.3 27 15 End Plate PFP-M 25 10 25 25 1,000 25 10 15 M4x8 panhead screw 50 1.8 1 35.5 35.3 1.8 11.5 10 1.3 4.8 M4 screw and washer Spacer PFP-S 16 12 5 34.8 44.3 16.5 Note 1: Order the above products in multiples of 10.
Warranty and Application Considerations Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON.