Datasheet

1
G
3
S
/
G
3
S
D
G3S/G3SD
Solid State Relays
Ultra-small Relay Breaks up to 1 A
Ultra-small, dual in-line package (DIP) SSR.
Terminals are compatible with G6B Electromagnetic Relay’s. Be
capable mix with G6Bs as the application requires.
Close mounting possible. In addition, heat sink dedicated to this
mounting style also available.
Both AC- and DC-load versions available.
High isolation of 2,500 VAC between input and output.
Built-in varistor effectively absorbs external surges (for AC switching).
Lineup includes models with UL and CSA certification (model numbers
ending in “-US”).
List of Models
*1. Product is labelled “250 VAC”. *2 Product is labelled “24 VDC”.
Ratings
Input (Each models has 5-VDC, 12-VDC, and 24-VDC input versions.)
Output
* The applicable output load current varies depending on the ambient temperature.
Refer to reference data the "Load Current vs. Ambient Temperature" rating characteristic for details.
Characteristics
RoHS Compliant
Refer to "Solid State Relays Common Precautions".
Isolation
Zero cross
function
Indicator Rated output load
Rated input
voltage
Model
Minimum
packing unit
Phototriac
No No
1 A
100 to 240 VAC *1
5 VDC
G3S-201PL
100 pcs
12 VDC
24 VDC
1.2 A
100 to 240 VAC *1
5 VDC
G3S-201PL-PD12 VDC
24 VDC
Photocoupler
1 A
4 to 24 VDC *2
5 VDC
G3SD-Z01P12 VDC
24 VDC
1.1 A
4 to 24 VDC *2
5 VDC
G3SD-Z01P-PD12 VDC
24 VDC
Rated
voltage
Operating voltage
Must operate
voltage level
Must release
voltage level
Impedance
G3S-201PL
G3S-201PL-PD
G3SD-Z01P
G3SD-Z01P-PD
5 VDC 4 to 6 VDC 4 VDC max.
1 VDC min.
450 Ω ±20% 630 Ω ±20%
12 VDC 9.6 to 14.4 VDC 9.6 VDC max. 1.1 kΩ ±20% 1.5 kΩ ±20%
24 VDC 19.2 to 28.8 VDC 19.2 VDC max. 2.2 kΩ ±20% 2.8 kΩ ±20%
Model Item Rated load voltage
Rated load voltage
range
Load current Inrush current
G3S-201PL
100 to 240 VAC 75 to 264 VAC
0.1 to 1 A *
15 A
(60 Hz, 1 cycle)
G3S-201PL-PD 0.1 to 1.2 A *
G3SD-Z01P
4 to 24 VDC 3 to 26 VDC
0.01 to 1 A *
3 A (10 ms)
G3SD-Z01P-PD 0.01 to 1.1 A *
Item Model G3S-201PL, G3S-201PL-PD G3SD-Z01P, G3SD-Z01P-PD
Operate time 1 ms max. 1 ms max.
Release time
1/2 of load power source cycle +
1 ms max.
1 ms max.
Output ON voltage drop 1.6 V (RMS) max. 1.5 V max.
Leakage current 2 mA (at 200 VAC) 0.1 mA max. (at 26 VDC)
Insulation resistance 100 MΩ min. (at 500 VDC)
Dielectric strength 2,500 VAC, 50/60 Hz for 1 min between input and output
Vibration resistance 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Shock resistance 1,000 m/s
2
Storage temperature 30°C to 100°C (with no icing or condensation)
Ambient operating temperature 30°C to 80°C (with no icing or condensation)
Ambient operating humidity 45% to 85% RH
Weight Approx. 13 g
Engineering Data
Load Current vs Ambient
Temperature Characteristics
One Cycle Surge Current: Non-repetitive
Non-repetitive (Keep the inrush current to half the
rated value if it occurs repetitively.)
1
0.75
0.5
0.25
0
1.25
1.2
1.1
30 20 0 20 40 60 80 100
Ambient temperature (°C)
Load current (A)
G3S-201PL-PD
G3SD-Z01P-PD
G3S-201PL
G3SD-Z01P
15
10
5
0
10 30 50 100 200 500 1,000 5,000
Energized time (ms)
Inrush current (A. Peak)
G3S-201PL
G3S-201PL-PD
3
2
1
0
10 30 50 100 200 500 1,000 5,000
Energized time (ms)
Inrush current (A. Peak)
G3SD-Z01P
G3SD-Z01P-PD