New Product Slim I/O Relay Global standard size, low profile slim I/O relay with width 6.2 mm, slim I/O solid state relay For the recent information on models that have been certified for safety standards, refer to your OMRON website. Refer to Safety Precautions on page 20. Slim I/O Relay Types G2RV-SR series mounted relay: electromagnetic relay ...... from page 2 G3RV-SR series mounted relay: solid state relay ................
Slim I/O Relay G2RV-SR G2RV-SR Global standard size, low profile slim I/O relay with width 6.2 mm G3RV-SR • Realized about 25% lower profile than conventional products, contributing to further miniaturization of the control panel. • Realized opening and closing ability with one pole 6 A slim shape. • Micro load products for one pole 50 mA using Au-plated contacts for small load switching also available.
G2RV-SR Model Number Structure Model Number Legend (1) (2) (3) (4) (5) (6) (1) Basic model name G2RV: Slim I/O Relay (2) Sub type SR: Slim relay + integrated low profile socket (3) Terminal (wire connection) 50: Push-In Plus Terminal 70: Screw terminal (5) Contact structure Blank: Standard AP: Microloads (4) Latching lever (test switch) 0: Without latching lever 1: With latching lever (6) Rated input voltage 12, 24 VDC 24, 48 VAC/VC 100, 110, 200, 230 VAC G2RV-SR G2RV-SR @@ @ - @ @ Ordering Inf
G2RV-SR Relay for Maintenance G2RV-SR Model Number Legend G2RV-1 - S @ - @ - G @ (1) (2) (3) (4) (5) (1) No.
G2RV-SR Specifications Ratings Must operate voltage Rated current Rated input voltage AC 50 Hz 12 VDC DC 60 Hz Must release voltage Percentage of the rated voltage Power consumption Maximum allowable voltage AC (VA) Percentage of the rated voltage DC (mW) 27.9 mA – Approx. 300 mW 13.5 mA – Approx. 300 mW 12.6 mA Approx. 0.5 VA Approx. 300 mW – – 24 VDC – – 24 VAC/VDC 12.5 mA 12.6 mA 48 VAC/VDC 5.9 mA 6.1 mA 5.2 mA 100 VAC 5.9 mA 6.0 mA – 110 VAC 5.9 mA 5.
G2RV-SR Approved standards G2RV-SR UL508 (file No.E41643) Model No. of poles G2RV-SR series Operation coil ratings 12 to 48 VDC 24 to 230 VAC SPDT Contact ratings Operations 6 A at 250 VAC (Resistive load) 6 A at 30 VDC (Resistive load) 6,000 2 A at 400 VAC (Resistive load)* * If the load voltage exceeds 250 VAC, please attach with a spacing of 12 mm min., or use a separate plate (XW5Z-EP12). 12 mm 12 mm 12 mm G3RV-SR TÜV (EN 61810-1) Model No.
G2RV-SR Dimensions (unit: mm) Slim I/O Relay + socket Push-In Plus Terminal Block Terminal Arrangement/Internal Connection Diagram (TOP VIEW) 12 VDC Input circuit A1 G2RV-SR Models without latching lever (without test switch) G2RV-SR500 78 max. G2RV-SR500-AP A2 G2RV 3.4 74.5 65.89 Other voltage 35.25 18.78 (5.05) Input circuit A1 G2RV 12 A2 14 11 78.77 G3RV-SR 90 max. 35.3 24 VDC Input circuit 12 A1 14 A2 G2RV 11 * : Diode bridge (5.05) : Light emitting diode 18.78 6.2 max.
G2RV-SR Screw terminal G2RV-SR Models without latching lever (without test switch) G2RV-SR700 G2RV-SR700-AP Terminal Arrangement/Internal Connection Diagram (TOP VIEW) 12 VDC Input circuit 78 max. A1 G2RV 3.4 A2 74.5 Other voltage 65.89 35.18 Input circuit 18.71 (5.05) A1 G2RV 12 A2 14 11 78.77 35.3 90 max. G3RV-SR 24 VDC Input circuit 12 A1 14 A2 G2RV 11 * (5.05) 18.71 : Diode bridge : Light emitting diode 35.18 6.2 max. 51.65 56.
G2RV-SR Relay for maintenance 5.2 max. G2RV-SR Models without latching lever G2RV-1-S-G G2RV-1-S-AP-G 30.5 max. Terminal Arrangement/ Internal Connection Diagram (TOP VIEW) 33 max. 16.2 0.5 14 11 12 A1 A2 G3RV-SR 1.8 (Input circuit) 2.4 3.5 5.04 5.04 22 3 Models with latching lever (test switch) G2RV-1-SI-G 30.5 max. Terminal Arrangement/ Internal Connection Diagram (TOP VIEW) (Input circuit) 36 max. 14 11 12 16.2 1.8 A1 A2 Common Precautions 5.2 max. 0.5 2.4 5.04 5.
Slim I/O Solid State Relay G2RV-SR G3RV-SR Global standard size, low profile type slim I/O solid state relay with width 6.2 mm. G3RV-SR • Realized about 25% lower profile than conventional products, contributing to further miniaturization of the control panel. • Optimal slim, high frequency, high-speed opening and closing SSR (solid state relay). • Realized a slim shape with a switching capacity up to 3 A (DC), and 2 A (AC).
G3RV-SR Model Number Structure Model Number Legend (1) (2) (3) (4) (5) (1) Basic model name G3RV: Slim I/O Solid State Relay (2) Sub type SR: Slim solid relay + integrated low profile socket (3) Terminal (wire connection) 500: Push-In Plus Terminal 700: Screw terminal (4) Output voltage specification A : AC output (triac) zero cross function available AL : AC output (triac) zero cross function not available D : DC output (MOS FET) G2RV-SR G3RV-SR @ @ @ - @ @ (5) Rated voltage input 12, 24 VDC 24,
G3RV-SR Ordering Information Terminal (wire connection) Applicable output load Zero cross function Rated input voltage (V) G2RV-SR DC AC/DC DC load — AC DC AC/DC Push-In Plus Terminal Yes G3RV-SR AC AC load DC AC/DC No AC Common Precautions DC AC/DC DC load — AC DC AC/DC Screw terminal Common Accessories 12 Yes AC AC load DC AC/DC No AC Model 12 G3RV-SR500-D DC12 24 G3RV-SR500-D DC24 24 G3RV-SR500-D AC/DC24 48 G3RV-SR500-D AC/DC48 100 G3RV-SR500-D AC100 110 G3RV-SR500-D AC110
G3RV-SR Solid state relay for maintenance G2RV-SR Model Number Legend G3RV-@ @ S @ @ (1) (2) (3) (4) (1) Output voltage specification D: DC output 2: AC output (5) (3) Terminal S: Plug-in type (4) Zero cross functions Blank: Zero cross function available L: Zero cross function not available (2) Rated current 02: AC output 2 A 03: DC output 3 A (5) Rated input voltage Number: 12, 24, 48 VDC List of Models Rated output Load * Rated input voltage (socket) 12 VDC 24 VDC 24 VAC/VDC Model G3RV-202S DC12
G3RV-SR Specifications Rating (ambient temperature 25°C) G2RV-SR Input G3RV-SR700/500-A series Rated current Rated input voltage AC 50 Hz DC 60 Hz Must operate voltage 12 VDC – – 15.0 mA 10.8 V max. 24 VDC – – 12.0 mA 21.6 V max. 24 VAC/VDC 11.3 mA 11.4 mA 11.0 mA 21.6 V max. 48 VAC/VDC 6.8 mA 6.9 mA 6.0 mA 43.2 V max. 100 VAC 6.2 mA 6.2 mA – 90 V max. 110 VAC 6.2 mA 6.2 mA – 99 V max. 200 VAC 3.7 mA 4.4 mA – 180 V max. 230 VAC 3.8 mA 4.6 mA – 207 V max.
G3RV-SR Characteristics G3RV-SR700/500-A G3RV-SR700/500-AL G3RV-SR700/500-D Operate time 1/2 cycle of load power supply +1 ms max. 3 ms max. 6 ms max. Release time 60 ms max. 60 ms max. 60 ms max. Output ON voltage drop 1.6 V (RMS) max. Output ON resistance – 0.3 Ω max. (at 24 VDC) – 5 mA max. (at 200 VAC, 50/60 Hz) 10 µA max. (at 24 VDC) Insulation resistance 100 MΩ min.
G3RV-SR Engineering Data Load current vs. ambient rated temperature Product mounting spacing 10 mm (Separate Mounting) Close mounting (up to 5 units *) 5 Load current (A) Load current (A) G2RV-SR G3RV-SR700/500-A(L) series 4 5 4 3 3 2 2 1 1 0 −30 −20 0 20 25 40 55 60 80 0.
G3RV-SR Dimensions (unit: mm) Solid state relay + socket Terminal Arrangement/ Internal Connection Diagram (TOP VIEW) 12 VDC G2RV-SR Push-In Plus Terminal Block G3RV-SR500 Input circuit 78 max. A1 G3RV A2 A2– 3.4 (5.05) INPUT 74.5 65.89 A1+ 13 (+) 35.25 18.78 OUTPUT 14 (–) 12 14 13 78.77 24 VDC 90 max. 35.3 Input circuit G3RV-SR The information in parentheses in for a DC output. A1 G3RV A2 A2– INPUT (5.05) A1+ 18.78 6.2 max. 35.25 OUTPUT 14 (–) 59.
G3RV-SR Screw terminal G3RV-SR700 G2RV-SR Terminal Arrangement/ Internal Connection Diagram (TOP VIEW) 12 VDC 78 max. Input circuit A1 3.4 74.5 G3RV 65.89 35.18 (5.05) A2 A2– 18.71 INPUT A1+ 13 (+) OUTPUT 14 (–) G3RV-SR 78.77 35.3 90 max. The information in parentheses in for a DC output. 12 14 13 24 VDC Input circuit A1 (5.05) 18.71 G3RV 35.18 A2 6.2 max. 51.65 56.2 A2– INPUT A1+ 13 (+) Common Precautions OUTPUT 14 (–) The information in parentheses in for a DC output.
G3RV-SR Solid state relay for maintenance Terminal Arrangement/ Internal Connection Diagram (TOP VIEW) G3RV-D03SL (input circuit) Input 30.5 max. Load G2RV-SR G3RV-D03SL G3RV-202S(L) 33 max. 15.8 14 1.8 3.5 13 A1 A2 G3RV-202S(L) (input circuit) 2.4 22 5.04 3 Input 5.2 max.
G2RV-SR/G3RV-SR Safety Precautions Be sure to read the Safety Precautions for All Relays in the website at the following URL: http://www.ia.omron.com/. G2RV-SR Format of Warning Indications WARNING Indicates a potentially hazardous situation which, if not avoided, will result in minor or moderate injury, or may result in serious injury or death. Additionally, there may be significant property damage.
G2RV-SR/G3RV-SR Mounting • Before you start wiring, please make sure that the socket is may come loose and risk of injury towards the workers. • Please insert the flat-blade screwdriver to the bottom of the hole. If • Do not use or store the product in the following locations. Doing so may result in damage, malfunction, or deterioration of performance characteristics.
G2RV-SR/G3RV-SR Checking Connections • After insertion, pull gently on the wire to make sure that it will not G2RV-SR come out (i.e., to confirm that it is held by the terminal block). • If you use a ferrule with a conductor length of 10 mm, part of the conductor may be visible after the ferrule is inserted into the Recommended Flat-blade Screwdriver Use a flat-blade screwdriver to connect and remove wires. Use the following flat-blade screwdriver.
G2RV-SR/G3RV-SR • Do not use the latching lever as a switch. • Operation durability of the latching lever is 100 times or more.
G2RV-SR/G3RV-SR For G2RV-SR/G3VR-SR G2RV-SR Common Accessories (order separately) Ordering Information Short Bars Appearance No. of poles Pitch Colors 2 Maximum energizing current PYDN-6.2-020@ 3 6.2 mm Minimum order (Quantity) Model * Red (R), Blue (S), Yellow (Y) 4 10 20 PYDN-6.2-030@ PYDN-6.2-040@ 10 32 A PYDN-6.2-100@ PYDN-6.2-200@ Note: Use for wiring to the adjacent socket. * Replace the box (@) in the model number with the code for the covering color.
G2RV-SR/G3RV-SR Applicable Cables Appearance End A Cables with Loose Wires P2RV-A@C 8 I/O points Device end Cables with Connectors (1:4) P2RV-4-@C P2RV-A200C 3,000 P2RV-A300C 5,000 P2RV-A500C 1,000 P2RV-4-100C 2,000 P2RV-4-200C 3,000 P2RV-4-300C 5,000 P2RV-4-500C 1,000 P2RV-4-100IMC 2,000 P2RV-4-200IMC 3,000 P2RV-4-300IMC 5,000 P2RV-4-500IMC 1,000 P2RV-4-100IFC 2,000 P2RV-4-200IFC 3,000 P2RV-4-300IFC 5,000 P2RV-4-500IFC 300 32 input points 8 output Cables with Connectors
G2RV-SR/G3RV-SR Name Appearance G2RV-SR End A 32 input points End B Device end PLC interface unit end 32 output points Schneider Electric PLC Connecting Cables P2RV-@C-SCH-@ L 300 G3RV-SR 16 input points 16 output points L 300 32 input points Common Precautions Common Accessories 26 32 output points Siemens PLC Connecting Cables P2RV-@C-SIM-@ L 300 16 input points L 300 32 input points 32 output points L 300 Cable length L (mm) Connecting Cables 500 P2RV-050C-SCH-A 1,000
G2RV-SR/G3RV-SR PLC interface unit G2RV-SR Ratings / characteristices Rated voltage 30 VAC/DC Rated current 0.5 A/poles, 2 A/unit Ambient operating temperature Vibration resistance Shock resistance −40 to 55°C Destruction 10 to 55 to 10 Hz, single amplitude 0.75 mm (double amplitude 1.5 mm) Malfunction 10 to 55 to 10 Hz, single amplitude 0.75 mm (double amplitude 1.5 mm) Destruction 300 m/s2 Malfunction 100 m/s2 Electrical schematic Input P2RVC-8-I-@-1 (PNP) 14 1....................
G2RV-SR/G3RV-SR Dimensions (unit: mm) PLC interface unit G2RV-SR Push-IN P2RVC-8-I-5(-1) P2RVC-8-O-5(-1) 49.60 67.16 G3RV-SR Common Precautions Common Accessories 28 12.68 7×6.20 29 Screw P2RVC-8-I-7-1 P2RVC-8-O-7-1 49.60 67.16 12.68 7×6.
G2RV-SR/G3RV-SR (Except for PLC interface unit) Common Accessories (unit: mm) Short Bars PYDN-6.2-@@ (6.2 mm) 2 L Pitch No. of poles 1.20 6.2 mm 9 6.20 14 L (Length) Colors Model * 2 12.4 PYDN-6.2-020@ 3 18.6 PYDN-6.2-030@ 4 24.8 10 62 20 124 Red (R) Blue (S) Yellow (Y) Maximum carry current PYDN-6.2-040@ G2RV-SR Dimensions 32 A PYDN-6.2-100@ PYDN-6.2-200@ Note: Use the Short Bars for crossover wiring within one Socket or between Sockets.
MEMO 30
Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron).
OMRON Corporation Industrial Automation Company Authorized Distributor: Kyoto, JAPAN Contact: www.ia.omron.com Regional Headquarters OMRON EUROPE B.V. Wegalaan 67-69, 2132 JD Hoofddorp The Netherlands Tel: (31)2356-81-300/Fax: (31)2356-81-388 OMRON ELECTRONICS LLC 2895 Greenspoint Parkway, Suite 200 Hoffman Estates, IL 60169 U.S.A. Tel: (1) 847-843-7900/Fax: (1) 847-843-7787 OMRON ASIA PACIFIC PTE. LTD. No.