Datasheet

1
Hall Coded Non-contact Safety Switches
F3S-TGR-N@C
Hall coded non-contact switches monitor the status of guarding doors.
Stainless steel housing for high hygiene demands in the food industry are available.
Based on hall technology
Connect up to 20 switches in series
LED supports easy diagnosis
Operates with all OMRON safety controllers
Operates behind stainless steel fittings
Non-contact – no abrasion – no particles
Compensation of mechanical tolerances
Suitable for high pressure cleaning, CIP/SIP
processes due IP69K (pre-wired types)
Conforms to safety categories up PLe acc.
EN ISO13849-1
Model Number Structure
1. Type
L: Elongated Sensor
S: Small Sensor
M: Miniature Sensor
B: Barell Sensor
2. Housing Material
P: Plastic Housing
M: Stainless Steel Housing
H: Hygienic designed Stainless Steel Housing
F: Special Food Type Stainless Steel Housing
3. Cable Length/connection
05: 5 m Cable
05-R*: 5 m Cable exit to the right
10: 10 m Cable
10-R*: 10 m Cable, exit to the right
M1J8: M12 male connector, 8 pin, fitted with 250 mm cable
M1J8-R*: M12 male connector, 8 pin, fitted with 250 mm cable
exit to the right
* only for F3S-TGR-NMPC and F3S-TGR-NMHC
F3S-TGR-N@@C-21-@@
12