Datasheet
F3S-TGR-CL@
7
F3S-TGR-CL-K system data
Wiring example
F3S-TGR-CL in automatic mode and G9SB-301-D in manual mode
A
L
E
I
L: Total length of the F3S-TGR-CL system
I: Beam distance
E: Detection zone
A: Dead zone without detection capability
Model code 500 800 900 1200
all
models
L [mm] 682 982 1,082 1,382
E [mm] 518 818 918 1,218
Weight [kg] 2.3 3.2 4.1 4.9
I [mm] 500 400 300 400
Mounting brackets
(F39-TGR-ST-SB)
included in shipment
46
+24 VDC (Brown)
Shield
Shield
OSSD1 (Pink)
OSSD2 (Gray)
0 VDC (Blue)
Mut. Lamp (Red)
Mut. B (Yellow)
Mut. A (Green)
Test/restart (White)
Feedback loop
+24 VDC (Brown)
0 VDC
Test (White)
F3S-TGR-CL
KM1 KM2
RECEIVERTRANSMITTER
K1
K2
A1 T11 T12 T21 T22 T31 T32 13 23 33 41
42342414A2
G9SB-301-D
CONTROL
CIRCUIT
K1
K2
S1
24 VDC +
-
M
KM1
KM2
S2
KM1
KM2
Note: This circuit achieves up to PLe according
to EN ISO 13849-1 with F3S-TGR-CL4
and up to PLc according to
EN ISO 13849-1 with F3S-TGR-CL2.