Datasheet

F3S-TGR-CL@
5
Finger- and hand safety protection sensors
Safety-related functions
All models with dip-switch setup for external device monitoring, interlock function, range setting (short
and long range) and optical or wired sync
Advanced models with selectable pre-reset function, T-, L-or X- muting function (timeout or infinite mut-
ing dip switch option) and muting lamp integrated
Response time ON to OFF: Maximum: 13 ms
Ambient temperature Operating: –10 to 55°C, Storage: –25°C to 70°C (no icing, no condensation)
Ambient humidity 95% not condensing
Degree of protection IP 65 (IEC 60529)
Materials
Housing: Painted aluminum, Yellow, RAL 1018
Front Window: Acrylic Lexan
Red end cap: PA6 (Standalone models),
Transparent end cap: PC (Advanced standalone models),
Sealing Gasket: EPDM
Mounting Bracket: Cold rolled Steel
Suitable for safety control systems PLc (ISO 13849-1) PLe (ISO 13849-1)
Category Categorie 2 Categorie 4
PFHd 2.5 × 10
-9
Proof test interval every 20 years
Item F3S-TGR-CL2_-0__ F3S-TGR-CL4_-0__
Sensor type Type 2 Type 4
Protective height 150 mm - 2,400 mm
Operating range:
(short setting or long setting)
F3S-TGR-CL__-014: 0.2 m to 3 m or 3 m to 6 m (Dip switch option)
F3S-TGR-CL__-035: 0.2 m to 7 m or 7 m to 14 m (Dip switch option)
F3S-TGR-CL__-070: 0,2 m to 7 m or 7 m to 14 m (Dip switch option)
Detection capability
F3S-TGR-CL__-014: Opaque objects 14 mm in diameter
F3S-TGR-CL__-035: Opaque objects 35 mm in diameter
F3S-TGR-CL__-070: Opaque objects 70 mm in diameter
Effective aperture angle (EAA)
Within ±5° Within ±2.5°
for the emitter and receiver at a detection distance of at least 3 m according to IEC 61496-2
Light source Infrared LED (880 nm), power dissipation <3 mW, Class 1 per EN 60825-1
Supply voltage 24 VDC ±20%, according EN 60204-1 able to cover a drop of voltage of at least 20 ms
OSSD 2 PNP transistor outputs, load current 2 × 250 mA max
Series connection
Number of connections: One master and one slave safety light curtain
Total number of beams 336
Maximum interconnect cable length: 900 mm
Test functions Self test (after power ON and during operation)
Safety-related functions
All models with dip-switch setup for external device monitoring, interlock function, range setting (short
and long range) and optical or wired sync.
Advanced models with selectable pre-reset function, T-, L-or X- muting function (timeout muting), blank-
ing, single / double brake function and muting lamp integrated
Response time ON to OFF: 14 ms to 103 ms
Ambient temperature Operating: –10°C to +55°C, Storage: –25°C to +70°C (no icing, no condensation)
Ambient humidity 95% not condensing
Degree of protection IP 65 (IEC 60529)
Materials
Housing: Painted aluminum, Yellow, RAL 1018
Front Window: Acrylic Lexan
Red end cap: PA6 (Standalone models),
Transparent end cap: PC (Advanced standalone models),
Die cast aluminium (Master-, Slave models)
Sealing Gasket: EPDM
Mounting Bracket: Cold rolled Steel
Suitable for safety control systems PLc (ISO 13849-1) PLe (ISO 13849-1)
Category Categorie 2 Categorie 4
PFHd 2,5 × 10
-9
Proof test interval every 20 years
Item F3S-TGR-CL2_-0__ F3S-TGR-CL4_-0__