12 Sensing Band F03-16SF
Sensing Band
F03-16SF
• Greater flexibility and superior workability compared with the
F03-16PE.
• The sheath becomes transparent to reveal the red inner sheath
if liquid leakage occurs, thereby enabling visual confirmation.
After drying, the Sensing Band color will return to white
(F03-16SFC only).
Ordering Information
Specifications
Length of Cable
■ Length of Cable (For reference only. Performance values may differ.)
(1) Connection with K7L-AT50 or K7L-AT50D (IV Cable + Sensing Band)
❍···Set value that can be used.
Note: These values are possible provided that a completely insulated 3-conductor VCT cable with a thickness of 0.75mm
2
and a dielectric strength
of 600 V is used.
Name Model number Remarks
Sensing Band F03-16SF Without color indication
F03-16SFC With color indication
Stickers F03-25 30 Stickers per bag
Sheath Special plastic fiber braided cable with water-absorbent and water-repellent characteristics
Core Tin-plated, copper stranded wire
Ambient operating temperature
−15 to 60°C
Fire retardancy Not fire retardant
Weight Approx. 20 g (1 m)
Sensing Band 0 m 10 m 50 m 100 m 150 m
Wiring Cable Note
0 m ❍❍❍❍❍
Range 3 Range 3 Range 2 Range 2 Range 1
10 m ❍❍❍❍❍
Range 3 Range 3 Range 2 Range 2 Range 1
50 m ❍❍❍❍❍
Range 3 Range 3 Range 2 Range 2 Range 1
100 m ❍❍❍❍❍
Range 3 Range 3 Range 2 Range 2 Range 1
150 m ❍❍❍❍❍
Range 3 Range 3 Range 2 Range 2 Range 1
200 m ❍❍❍❍❍
Range 3 Range 3 Range 2 Range 2 Range 1