Datasheet
EE-SPY31/41
96
Safety Precautions
Refer to Warranty and Limitations of Liability.
This product is not designed or rated for ensuring
safety of persons either directly or indirectly.
Do not use it for such purposes.
Make sure that this product is used within the rated ambient
environment conditions.
● Wiring
• Connection is made using a connector. Do not solder to the pins
(leads).
• When extending the cable, use an extension cable with conductors
having a total cross-section area of 0.3 mm
2
. The total cable length
must be 2 m maximum.
• To use a cable length longer than 2 m, attach a capacitor with a
capacitance of approximately 10 μF to the wires as shown below.
The distance between the terminal and the capacitor must be within
2 m. (Use a capacitor with a dielectric strength that is at least twice
the Sensor's power supply voltage.)
• Make sure the total length of the power cable connected to the
product is less than 10 m even if a capacitor is inserted.
(Unit: mm)
Dimensions Tolerance class IT16 applies to dimensions in this datasheet unless otherwise specified.
Sensors
WARNING
Precautions for Correct Use
2 m max.
A capacitor of
10 μF min.
5 to 24 DCV
0 V
Extension cable
OUT
Accessories (Order Separately)
*Refer to Accessories for details.
Terminal Arrangement
(1) + Vcc
(2) OUT OUTPUT
(3) − GND (0 V)
EE-SPY311
EE-SPY411
26
19
20
20
19
7.6
18.7
0.2
14
8
16.8
22.8
13.7
3.2
6.2
5 2.5
0.3 0.7
3.2
Four, R1
Four, R1.6
Sensing face
(back) (10 x 5)
Indicator window
(red)
Four,
R2.1
(1) (2)(3)
EE-SPY312
EE-SPY412
Terminal Arrangement
(1) + Vcc
(2) OUT OUTPUT
(3) − GND (0 V)
26
20
20
19
7.6
8
14
8
16.8
22.8
13.7
3.2
6.2
5 2.5
0.3 0.7
3.2
Four, R1
Four, R1.6
Sensing face
(10 × 5)
Indicator window
(red)
Four,
R2.1
0.2
19
(1) (2)(3)