Datasheet
EE-SPX-W
73
Engineering Data (Typical)
Safety Precautions
Refer to Warranty and Limitations of Liability.
This product is not designed or rated for ensuring
safety of persons either directly or indirectly.
Do not use it for such purposes.
Make sure that this product is used within the rated ambient
environment conditions.
● Wiring
• When extending the cable, use an extension cable with conductors
having a total cross-section area of 0.3 mm
2
. The total cable length
must be 2 m maximum.
• To use a cable length longer than 2 m, attach a capacitor with a
capacitance of approximately 10 μF to the wires as shown below.
The distance between the terminal and the capacitor must be within
2 m. (Use a capacitor with a dielectric strength that is at least twice
the Sensor's power supply voltage.)
• Make sure the total length of the power cable connected to the
product is less than 10 m even if a capacitor is inserted.
Sensing Position Characteristics
EE-SPX302-W2A
EE-SPX304-W2A
EE-SPX306-W2A
EE-SPX302-W2A
EE-SPX304-W2A
EE-SPX306-W2A
EE-SPX305-W2A EE-SPX305-W2A
0123456
Tr ON
Tr OFF
d
d
Dark-ON
Distance d (mm)
0123456
Tr ON
Tr OFF
d
Dark-ON
Distance d (mm)
Tr ON
Tr OFF
0123456
EE-SPX305-W2A
d
Dark-ON
Distance d
(
mm
)
Tr ON
Tr OFF
d
Dark-ON
012345
6
Distance d
(
mm
)
WARNING Precautions for Correct Use
+
−
A capacitance of
10 μF min.
5 to 24 VDC
2 m max.
0 V
+
−
Extension cable