Datasheet

EE-SA701/801
119
Safety Precautions
Refer to Warranty and Limitations of Liability.
This product is not designed or rated for ensuring
safety of persons either directly or indirectly. Do not
use it for such purposes.
Make sure that the Photomicrosensor is used within the rated ambient
environment conditions.
Mounting
Mount the Photomicrosensor securely on a flat surface using M3 pan
head screws, and tighten the mounting screws using a tightening
force of 0.59 N·m max.
Adjustment
The EE-SA801 requires 10 ms to be in stable operation after power is
supplied. If separate power supplies are used for the EE-SA801 and
load, be sure to supply power to the EE-SA801 before supplying
power to the load.
Operating Environment
The EE-SA801 is not watertight. Do not use the EE-SA801
outdoors.
Do not use the EE-SA801 in places where water, oil, or chemical
may be sprayed onto the EE-SA801. The exterior coverings of the
EE-SA801 are made of polycarbonate. Keep the coverings away
from any alkaline, aromatic hydrocarbon, or aliphatic chloride
hydrocarbon solvents, all of which will damage the coverings.
(Unit: mm)
Dimensions Tolerance class IT16 applies to dimensions in this datasheet unless otherwise specified.
Sensor
WARNING
Precautions for Correct Use
13±0.2
Indicator window
20±0.3
6.5±0.1
21.3±0.2
25±0.3
9±0.2
18±0.2
14
2.24
2.24
3
3
Four, R3
Six, R3
1,000±50
4
4
5±0.4
SR4
Indicator window
Indicator window
Two, 3.3-dia. holes with 6.3 countersinking, depth: 1.65
(14)
(2.8 dia.)
EE-SA801A/EE-SA801R
Vinyl-insulated round cable of 2.8 dia., 4 cores,
(0.14 mm
2
conductor cross-sectional area with
0.85-mm dia. insulator); Standard length: 1 m
EE-SA801A-R/EE-SA801R-R
EE-SA701-R/EE-SA701P-R
Cable for robot instrumentation of 2.8 dia., 4 cores,
(0.15 mm
2
conductor cross-sectional area with
0.8-mm dia. insulator); Standard length: 1 m
EE-SA801A/-SA801A-R
EE-SA801R/-SA801R-R
EE-SA701-R
EE-SA701P-R