Datasheet
EE-SA701/801
116
Ratings and Specifications
Note: 1. Free position (FP): The position of the top of the actuator when no force is being applied to the actuator.
Operating position (OP): The position of the top of the actuator when the actuator is pressed and the output transistor changes from OFF to ON for the EE-
SA701-R/-SA701P-R and from ON to OFF for all other models.
Total travel position (TTP): The position of the top of the actuator when the actuator is pressed as far as it can be pressed.
2. This does not indicate that the output will be ON from 3.5 to 4.5 mm, but rather that the output will change from ON to OFF at some point between 3.5 and
4.5 mm.
3. The force required to press the actuator from the FP to the OP.
Item
Model
NPN output EE-SA801A EE-SA801A-R EE-SA701-R
PNP output EE-SA801R EE-SA801R-R EE-SA701P-R
Indicator Lights red when actuator is pressed.
Lit red while there is no load on
actuator
Operation
Specifica-
tions (See
Free position (FP) 5.0±0.4 mm
Operating position (OP) 3.5 to 4.5 mm (See note 2.)
Total travel position (TTP) 0 mm max.
Operating load (See note 3.) 3 N max. (typical: 0.5 N)
Supply voltage 12 to 24 VDC±10%, ripple (p-p): 10% max.
Current consumption 35 mA max.
Control output
NPN Models: NPN open collector, 5 to 24 VDC, 50 mA max.;
residual voltage of 0.4 V max. at 50-mA load current
OFF current: 0.5 mA max.
PNP Models: PNP open collector, 5 to 24 VDC, 50 mA max.;
residual voltage of 0.4 V max. at 50-mA load current
OFF current: 0.5 mA max.
External diagnosis input
Input
NPN Models
Emission OFF: Shorted to 0 V or 0.5 V max. (source current: 30 mA max.)
Emission ON: Open (leakage current: 0.4 mA max.)
PNP Models
Emission OFF: Shorted to +DC or +DC-0.5 V max. (sink current: 30 mA max.)
Emission ON: Open (leakage current: 0.4 mA max.)
Response time 1 ms max.
Protection circuits Reversed power supply polarity protection
Ambient temperature range
Operating: −25 to +55°C
Storage: −30 to +60°C (with no icing or condensation)
Ambient humidity range
Operating: 5% to 85%
Storage: 5% to 95% (with no condensation)
Mechanical durability
5,000,000 operations min. (One operation is from the free position to operating position and
back to the free position.)
Vibration resistance
Destruction: 10 to 500 Hz, 1.0-mm single amplitude or 150 m/s
2
3 times each in X, Y, and Z di-
rections for 11 min. each
Shock resistance Destruction: 500 m/s
2
for 3 times each in X, Y, and Z directions
Degree of protection IEC IP40
Connecting method
Pre-wired (standard cable
length: 1 m)
Pre-wired (robot cable length: 1 m)
Weight Approx. 16.1 g
Material
Case Polycarbonate
Actuator Polyacetal
Accessories Instruction Manual
TTP
OP
FP