Brochure

14
E5_C-T Advanced and Multi-Loop controllers
Compact and intelligent Ramp/Soak controller
The E5_C-T Ramp/Soak temperature controllers expands the E5_C family to handle
process applications. Capable of addressing up to 6 event inputs and up to 4 auxiliary
outputs all in a compact 60 mm (depth) housing, makes this controller series one of
Omron's most powerful and versatile temperature controllers.
Set up to 8 programs with 32 segments totaling 256 program segments simply via
CX-Thermo software.
The three-level display is visible simultaneously so each process status can be easily
identified.
“Segment Jump” allows users to move directly to the specified segment reducing
programming time and increase production throughput.
Ordering information
E5CC-T
E5AC-T/E5EC-T
Input Output Alarms HB
*1
alarm & SSR
*2
defect detection
*1
HB = Heater burnout
*2
SSR = Solid state relay
Comm. (RS-485) Event Input Transfer
output
Order code
100 to 240 VAC 24 VAC/VDC
Temperature sensor/
analog
Out 1: Relay
Out 2: None
3––––
E5CC-TRX3A5M-000 E5CC-TRX3D5M-000
12
E5CC-TRX3A5M-001 E5CC-TRX3D5M-001
2
*3
*3
3-Phase heater burnout alarm
1–
E5CC-TRX3A5M-003 E5CC-TRX3D5M-003
–2
E5CC-TRX3A5M-004 E5CC-TRX3D5M-004
–4
E5CC-TRX3A5M-005 E5CC-TRX3D5M-005
2Y
E5CC-TRX3A5M-006 E5CC-TRX3D5M-006
Out 1: Voltage (pulse)
Out 2: None
––
E5CC-TQX3A5M-000 E5CC-TQX3D5M-000
12
E5CC-TQX3A5M-001 E5CC-TQX3D5M-001
2
*3
1– E5CC-TQX3A5M-003 E5CC-TQX3D5M-003
–2
E5CC-TQX3A5M-004 E5CC-TQX3D5M-004
–4
E5CC-TQX3A5M-005 E5CC-TQX3D5M-005
2Y
E5CC-TQX3A5M-006 E5CC-TQX3D5M-006
Out 1: Current linear
Out 2: None
––
E5CC-TCX3A5M-000 E5CC-TCX3D5M-000
12
E5CC-TCX3A5M-004 E5CC-TCX3D5M-004
–4
E5CC-TCX3A5M-005 E5CC-TCX3D5M-005
2Y
E5CC-TCX3A5M-006 E5CC-TCX3D5M-006
Out 1: Voltage (pulse)
Out 2: Voltage (pulse)
––
E5CC-TQQ3A5M-000 E5CC-TQQ3D5M-000
12
E5CC-TQQ3A5M-001 E5CC-TQQ3D5M-001
2
*3
1– E5CC-TQQ3A5M-003 E5CC-TQQ3D5M-003
–2
E5CC-TQQ3A5M-004 E5CC-TQQ3D5M-004
–4
E5CC-TQQ3A5M-005 E5CC-TQQ3D5M-005
2Y
E5CC-TQQ3A5M-006 E5CC-TQQ3D5M-006
Out 1: Current linear
Out 2: Voltage (pulse)
––
E5CC-TCQ3A5M-000 E5CC-TCQ3D5M-000
12
E5CC-TCQ3A5M-004 E5CC-TCQ3D5M-004
–4
E5CC-TCQ3A5M-005 E5CC-TCQ3D5M-005
2Y
E5CC-TCQ3A5M-006 E5CC-TCQ3D5M-006
Input Output Alarms HB
*1
alarm & SSR
*2
defect detection
*1
HB = Heater burnout
*2
SSR = Solid state relay
Comm. (RS-485) Event Input Transfer
output
Order code
*3
*3
Replace “_” with “A” for E5AC or “E” for E5EC
Model: 100 to 240 VAC Model: 24 VAC/VDC
Temperature sensor/
analog
Out 1: Relay
Out 2: None
4––––
E5_C-TRX4A5M-000 E5_C-TRX4D5M-000
112
E5_C-TRX4A5M-008 E5_C-TRX4D5M-008
–4
E5_C-TRX4A5M-010 E5_C-TRX4D5M-010
6Y
E5_C-TRX4A5M-019 E5_C-TRX4D5M-019
Out 1: Voltage (pulse)
Out 2: None
––
E5_C-TQX4A5M-000 E5_C-TQX4D5M-000
112
E5_C-TQX4A5M-008 E5_C-TQX4D5M-008
–4
E5_C-TQX4A5M-010 E5_C-TQX4D5M-010
6Y
E5_C-TQX4A5M-019 E5_C-TQX4D5M-019
Out 1: Current linear
Out 2: None
––
E5_C-TCX4A5M-000 E5_C-TCX4D5M-000
12
E5_C-TCX4A5M-004 E5_C-TCX4D5M-004
–4
E5_C-TCX4A5M-005 E5_C-TCX4D5M-005
6Y
E5_C-TCX4A5M-021 E5_C-TCX4D5M-021
14Y
E5_C-TCX4A5M-022 E5_C-TCX4D5M-022
E5_C-T_rev02.fm Seite 14 Donnerstag, 30. Oktober 2014 10:49 10
E5_C-T Advanced and Multi-Loop controllers
15
E5AC-T/E5EC-T
Specifications
E5CC-T/E5AC-T/E5EC-T
E5CC-T/E5AC-T/E5EC-T series optional tools
E5CC-T/E5AC-T/E5EC-T series software
Input Output Alarms HB
*1
alarm & SSR
*2
defect detection
*1
HB = Heater burnout
*2
SSR = Solid state relay
Comm. (RS-485) Event Input Transfer
output
Order code
*3
*3
Replace “_” with “A” for E5AC or “E” for E5EC
Model: 100 to 240 VAC Model: 24 VAC/VDC
Temperature sensor/
analog
Out 1: Current linear
Out 2: Current linear
4––––
E5_C-TCC4A5M-000 E5_C-TCC4D5M-000
12
E5_C-TCC4A5M-004 E5_C-TCC4D5M-004
–4
E5_C-TCC4A5M-005 E5_C-TCC4D5M-005
6Y
E5_C-TCC4A5M-021 E5_C-TCC4D5M-021
14Y
E5_C-TCC4A5M-022 E5_C-TCC4D5M-022
Out 1: Relay
Out 2: Relay
–––
E5_C-TRR4A5M-000 E5_C-TRR4D5M-000
112
E5_C-TRR4A5M-008 E5_C-TRR4D5M-008
–4
E5_C-TRR4A5M-010 E5_C-TRR4D5M-010
6Y
E5_C-TRR4A5M-019 E5_C-TRR4D5M-019
Out 1: Voltage (pulse)
Out 2: Voltage (pulse)
––
E5_C-TQQ4A5M-000 E5_C-TQQ4D5M-000
112
E5_C-TQQ4A5M-008 E5_C-TQQ4D5M-008
–4
E5_C-TQQ4A5M-010 E5_C-TQQ4D5M-010
6Y
E5_C-TQQ4A5M-019 E5_C-TQQ4D5M-019
Out 1: Voltage (pulse)
Out 2: Relay
––
E5_C-TQR4A5M-000 E5_C-TQR4D5M-000
112
E5_C-TQR4A5M-008 E5_C-TQR4D5M-008
–4
E5_C-TQR4A5M-010 E5_C-TQR4D5M-010
6Y
E5_C-TQR4A5M-019 E5_C-TQR4D5M-019
Out 1: Current linear
Out 2: Voltage (pulse)
––
E5_C-TCQ4A5M-000 E5_C-TCQ4D5M-000
112
E5_C-TCQ4A5M-008 E5_C-TCQ4D5M-008
–4
E5_C-TCQ4A5M-010 E5_C-TCQ4D5M-010
6Y
E5_C-TCQ4A5M-019 E5_C-TCQ4D5M-019
Out 1: Relay
Out 2: Relay
(Valve control)
––
E5_C-TPR4A5M-000 E5_C-TPR4D5M-000
12
E5_C-TPR4A5M-004 E5_C-TPR4D5M-004
4Y
E5_C-TPR4A5M-022 E5_C-TPR4D5M-022
E5CC-T E5EC-T E5AC-T
Sizes in mm (W × H × D) 48×48×60 48×96×60 96×96×60
Supply voltage 100 to 240 VAC 50/60Hz or 24 VAC/VDC
Sensor input Temperature input Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II Platinum resistance thermometer: Pt100 or JPt100 Infrared temperature
sensor (ES1B): 10 to 70°C, 60 to 120°C, 115 to 165°C, or 140 to 260°C Analog input Current input: 4 to 20 mA or 0 to 20 mA Voltage input: 1 to 5 V,
0 to 5 V, or 0 to 10 V
Control mode 2-PID control (with auto-tuning) or ON/OFF control
Accuracy Thermocouple: (±0.3% of indication value or ±1°C, whichever is greater) ±1 digit max. /Platinum resistance thermometer: (±0.2% of indication
value or ±0.8°C, whichever is greater) ±1 digit max.Analog input: ±0.2% FS ±1 digit max.CT input: ±5% FS ±1 digit max.Potentiometer input:
±5% FS ±1 digit max.
Functions Manual output, heating/cooling control, loop burnout alarm, other alarm functions, heater burnout (HB) alarm (including SSR failure (HS) alarm),
40% AT, 100% AT, MV limiter, input digital filter, robust tuning, PV input shift, protection functions, extraction of square root, MV change rate
limit, logic operations, temperature status display, moving average of input value, and display brightness setting
Programs / segments 8/32
PID sets 8
Communication RS-485 (multi-drop), CompowayF or Modbus RTU
Event inputs 2-6
QLP (Quick link port) Yes, via USB and E58-CIFQ2 conversion cable
Ambient temperature –10 to 55 °C
IP rating of front panel IP66
Sampling period time 50 ms
USB PC based configuration cable E58-CIFQ2 for E5CC-T
E58-CIFQ2 (& E58-CIFQ2-E) for E5AC-T and E5EC-T
CX-Thermo >4.62 Professional parameterization and cloning software, data-logging, Fine-Tuning, logic operations, easy setting of process steps
Operation system: Microsoft Windows XP (Service Pack 3 or higher)/Vista/7/8
E5_C-T_rev02.fm Seite 15 Donnerstag, 30. Oktober 2014 10:49 10