Brochure
E5_C General purpose temperature controllers
10
E5GC (models with 0, 1 or 2 auxiliary outputs)
E5DC (models with 0 or 2 auxiliary outputs)
Output Terminal type Option No Fixed option Order code
110-240 VAC 24 VAC/VDC
Out 1: Relay Screw terminals
(with cover)
––
E5GC-RXOA6M-OOO E5GC-RXOD6M-OOO
E5GC-RX1A6M-OOO E5GC-RX106M-OOO
E5GC-RX2A6M-OOO E5GC-RX206M-OOO
015 Communication
E5GC-RX1A6M-015 E5GC-RX106M-015
E5GC-RX2A6M-015 E5GC-RX206M-015
016 Event input 1
E5GC-RX2A6M-016 E5GC-RX206M-016
023 Heater Burnout SSR defect detection
E5GC-RX2A6M-023 E5GC-RX206M-023
024 Event input 2
E5GC-RX1A6M-024 E5GC-RX106M-024
Screwless clamp terminal – –
E5GC-RXOACM-OOO E5GC-RXODCM-OOO
E5GC-RX1ACM-OOO E5GC-RX1DCM-OOO
E5GC-RX2ACM-OOO ESGC-RX2DCM-OOO
015 Communication
E5GC-RX1ACM-015 E5GC-RX1DCM-015
ESGC-RX2ACM-015 E5GC-RX2DCM-015
016 Event input 1
ESGC-RX2ACM-016 ESGC-RXZDCM-016
023 Heater Burnout SSR defect detection
ESGC-RX2ACM-023 ESGC-RXZDCM-023
024 Event input 2
ESGC-RX1ACM-024 ESGC-RX1DCM-024
Out 1: Voltage (pulse) Screw terminals
(with cover)
––
E5GC-OXOA6M-OOO E5GC-OXOD6M-OOO
E5GC-OX1A6M-OOO E5GC-OX106M-OOO
E5GC-OX2A6M-OOO E5GC-OX206M-OOO
015 Communication
E5GC-OX1A6M-015 E5GC-OX106M-015
E5GC-OX2A6M-015 E5GC-OX206M-015
016 Event input 1
E5GC-OX2A6M-016 E5GC-OX206M-016
023 Heater Burnout SSR defect detection
E5GC-OX2A6M-023 E5GC-OX206M-023
024 Event input 2
E5GC-OX1A6M-024 E5GC-OX106M-024
Screwless clamp terminal – –
E5GC-OXOACM-OOO E5GC-OXODCM-OOO
E5GC-OX1ACM-OOO E5GC-OX1DCM-OOO
ESGC-OX2ACM-OOO ESGC-OX2DCM-OOO
015 Communication
E5GC-OX1ACM-015 E5GC-OX1DCM-015
E5GC-OX2ACM-015 E5GC-OX2DCM-015
016 Event input 1
ESGC-OX2ACM-016 ESGC-OX2DCM-016
023 Heater Burnout SSR defect detection
ESGC-OX2ACM-023 ESGC-OX2DCM-023
024 Event input 2
ESGC-OX1ACM-024 ESGC-OX1DCM-024
Out 1: Liner current Screw terminals
(with cover)
––
E5GC-CXOA6M-OOO E5GC-CXOD6M-OOO
E5GC-CX1A6M-OOO E5GC-CX106M-OOO
E5GC-CX2A6M-OOO E5GC-CX206M-OOO
015 Communication
E5GC-CX1A6M-015 E5GC-CX106M-015
E5GC-CX2A6M-015 E5GC-CX206M-015
016 Event input 1
E5GC-CX2A6M-016 E5GC-CX206M-016
024 Event input 2
E5GC-CX1A6M-024 E5GC-CX106M-024
Screwless clamp terminal – –
ESGC-CXOACM-000 ESGC-CXODCM-000
E5GC-CX1ACM-OOO E5GC-CX10CM-OOO
E5GC-CX2ACM-OOO E5GC-CX20CM-OOO
015 Communication
E5GC-CX1ACM-015 E5GC-CX10CM-015
E5GC-CX2ACM-015 E5GC-CX20CM-015
016 Event input 1
E5GC-CX2ACM-016 E5GC-CX20CM-016
024 Event input 2
E5GC-CX1ACM-024 E5GC-CX10CM-024
Output Option No Fixed option Order code
110-240 VAC 24 VAC/VDC
Out1: Relay – –
E5DC-RX2ASM-000 E5DC-RX2DSM-000
002 Communication,
Heater Burnout SSR defect detection
E5DC-RX2ASM-002 E5DC-RX2DSM-002
015 Communication
E5DC-RX0ASM-015
*1
*1
Auxiliary outputs are not possible for these models.
E5DC-RX0DSM-015
*1
017 Event Input 1,
Heater Burnout SSR defect detection
E5DC-RX2ASM-017 E5DC-RX2DSM-017
Out1: Voltage (pulse) – –
E5DC-QX2ASM-000 E5DC-QX2DSM-000
002 Communication,
Heater Burnout SSR defect detection
E5DC-QX2ASM-002 E5DC-QX2DSM-002
015 Communication
E5DC-QX0ASM-015
*1
E5DC-QX0DSM-015
*1
017 Event Input 1,
Heater Burnout SSR defect detection
E5DC-QX2ASM-017 E5DC-QX2DSM-017
Out1: Linear curent – –
E5DC-CX2ASM-000 E5DC-CX2DSM-000
015 Communication
E5DC-CX0ASM-015
*1
E5DC-CX0DSM-015
*1
015 Communication E5DC-CX2ASM-015 E5DC-CX2DSM-015
016 Event Input 1
E5DC-CX2ASM-016 E5DC-CX2DSM-016
E5_C_rev05_EN.fm Seite 10 Donnerstag, 30. Oktober 2014 10:40 10
E5_C General purpose temperature controllers
11
E5_C optional tools
Specifications
E5CC/E5EC/E5AC
Option Order code
USB based configuration cable
E58-CIFQ2, E58-CIFQ2-E (for E5AC, E5DC, E5EC and E5GC)
PC based configuration and tuning software
EST2-2C-MV4
Item E5CC E5EC E5AC
Power supply voltage A in model number: 100 to 240 VAC, 50/60 Hz
D in model number: 24 VAC, 50/60 Hz; 24 VDC
Operating voltage range 85% to 110% of rated supply voltage
Power consumption 6.5 VA max. at 100 to 240 VAC, and
4.1 VA max. at 24 VAC or
2.3 W max. at 24 VDC
8.3 VA max. at 100 to 240 VAC, and
5.5 VA max. at 24 VAC or
3.2 W max. at 24 VDC
9.0 VA max. at 100 to 240 VAC, and
5.6 VA max. at 24 VAC or
3.4 W max. at 24 VDC
Sensor input • Temperature inputs
Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II
Platinum resistance thermometer: Pt100 or JPt100
Infrared temperature sensor (ES1B): 10 to 70°C, 60 to 120°C, 115 to 165°C, or 140 to 260°C
• Analog inputs
Current input (mA): 4 to 20 or 0 to 20
Voltage input (V): 1 to 5, 0 to 5, or 0 to 10
Input impedance Current input: 150 max., Voltage input: 1 M min.
(Use a 1:1 connection when connecting the ES2-HB/THB.)
Control method ON/OFF control or 2-PID control (with auto-tuning)
Indication accuracy Thermocouple input: (±0.3% of indicated
value or ±1°C, whichever is greater)
±1 digit max.
Platinum resistance thermometer input:
(±0.2% of indicated value or ±0.8°C,
whichever is greater) ±1 digit max.
Analog input: ±0.2% FS ±1 digit max.
CT input: ±5% FS ±1 digit max.
Thermocouple input: (±0.3% of indicated value or ±1°C, whichever is greater)
±1 digit max.
Platinum resistance thermometer input: (±0.2% of indicated value or ±0.8°C, which-
ever is greater) ±1 digit max.
Analog input: ±0.2% FS ±1 digit max.
CT input: ±5% FS ±1 digit max.
Potentiometer input: ±5% FS ±1 digit max.
Auto-Tuning Yes, 40%/100% MV output limit selection. When using Heat/Cool: Automatic cool gain adjustment
Self-Tuning Yes
Control outputs Relay output SPST-NO, 250 VAC, 3 A (resistive load),
electrical life: 100,000 operations,
minimum applicable load: 5 V, 10 mA
SPST-NO, 250 VAC, 5 A (resistive load),
electrical life: 100,000 operations,
minimum applicable load: 5 V, 10 mA
Voltage output (for driving SSR) Output voltage: 12 VDC ±20% (PNP), max.
load current: 21 mA, with short-circuit
protection circuit
Output voltage: 12 VDC ±20% (PNP),
max. load current: 40 mA, with short-circuit protection circuit
(The maximum load current is 21 mA for models with two control outputs.)
Linear current output 4 to 20 mA DC/0 to 20 mA DC, load: 500 max., resolution: approx. 10,000
Auxiliary outputs Number of outputs 34
Output specifications N.O. relay outputs, 250 VAC,
Models with 3 outputs: 2 A (resistive
load), electrical life: 100,000 operations,
minimum applicable load: 5 V, 10 mA
N.O. relay outputs, 250 VAC,
Models with 4 outputs: 2 A (resistive load),
electrical life: 100,000 operations,
minimum applicable load: 5 V, 10 mA
Event inputs Number of inputs 2 or 4 or 6 max (depends on the model)
External contact input specifications Contact input: ON: 1 k max., OFF: 100 k min.
Non-contact input: ON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max.
Current flow: approx. 7 mA per contact
Setting method Digital setting using front panel keys or via Remote Software CX-Thermo V4.5
Indication method 11-segment digital display and individual indicators
Multi SP Up to eight set points (SP0 to SP7) can be saved and selected using event inputs, key operations, or serial communications.
Other functions Manual output, heating/cooling control, loop burnout alarm, SP ramp, other alarm functions, heater burnout detection (includ-
ing SSR failure detection), 40% AT, 100% AT, MV limiter, input digital filter, self-tuning, temperature input shift, run/stop, pro-
tection functions, extraction of square root, MV change rate limit, logic operations, PV/SV status display, simple program,
automatic cooling coefficient adjustment
Ambient operating temperature –10 to 55°C (with no condensation or icing)
Ambient operating humidity 25% to 85%
Storage temperature –25 to 65°C (with no condensation or icing)
Degree of protection Front panel: IP66, Rear case: IP20, Terminals: IP00
Sampling period 50 ms
Size in mm (H×W×D) 48×48×64 48×96×64 96×96×64
E5_C_rev05_EN.fm Seite 11 Donnerstag, 30. Oktober 2014 10:40 10