User Manual
222
Appendix A
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
a-m
m-sp
0
25
C
25
0
C
sp-m
0
C
ct1
0.0
ct2
0.0
lcr1
0.0
lcr2
0.0
prst
rset
sktr
0
r-s
run
al-1
0
C
al1h
0
C
al1l
0
C
al-2
0
C
al2h
0
C
al2l
0
C
al-3
0
C
al3h
0
C
al3l
0
C
o
0.0
c-o
0.0
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
cmwt
off
ct1
0.0
l.adj
at
off
ct2
0.0
lcr1
0.0
lcr2
0.0
hb1
0.0
hb2
0.0
hs1
50.0
hs2
50.0
sp-0
0
C
sp-1
0
C
sp-2
0
C
sp-3
0
C
ins
0.0
C
insh
0.0
C
p
8.0
C
i
233
d
40
c-sc
1.00
c-db
0.0
C
of-r
50.0
hys
1.0
C
chys
1.0
C
soak
1
wt-b
off
C
mv-s
0.0
mv-e
0.0
sprt
off
C
ol-h
105.0
ol-l
-5.0
M
M
M
M
M
M
M
psel
cwf
u-no
1
bps
9.6
len
7
sbit
2
prty
even
sdwt
20
M
M
M
M
M
M
pmov
0
oapt
0
icpt
1
wtpt
off
pmsk
on
prlp
0
25
C
M
insl
0.0
C
Power ON
Starting in manual mode.
Manual control level
PID control
only
PV/MV
Press the
O Key for
at least 1 s
Press the O Key for at
least 3 s. Displays other than
that for switching between
automatic and manual.
Adjustment Level
Press the O Key less than 1 s.
Press the O Key less than 1 s.
Operation Level
Adjustment level display
Displayed only once when
entering adjustment level.
AT execute/cancel
Communications writing
Heater current 1 value
monitor
Heater current 2 value
monitor
Leakage current 1
monitor
Leakage current 2
monitor
HS alarm 1
HS alarm 2
Heater burnout detection 1
Heater burnout detection 2
SP 0
SP 3
SP 2
SP1
SP used by
multi-SP
Temperature input shift
1-point shift
Set either of these parameters.
Upper-limit temperature
input shift value
2-point shift
Lower-limit temperature
input shift value
Proportional band
Integral time
PID settings
Derivative time
Cooling coefficient
Heating/cool-
ing
Dead band
Manual reset value
Clear the offset during sta-
bilization of P or PD control.
Hysteresis (heat)
Hysteresis
settings
Hysteresis (cool)
Soak time
Wait band
MV at stop
MV at PV error
SP ramp set value
MV upper limit
MV lower limit
Process value
Added when Additional
PV display is ON.
Auto/manual switch
PID control only.
Added when auto/manual
select addition is ON.
Press the
O Key for
at least 3 s.
Multi-SP
set point setting
Heater current 1 value
monitor
Heater current 2 value
monitor
Leakage current 1
monitor
Leakage current 2
monitor
Program start
RUN/STOP
Alarm value 1
Set either of these parameters.Set either of these parameters. Set either of these parameters.
Alarm value
upper limit 1
Alarm value
lower limit 1
Alarm value 2
Alarm value
upper limit 2
Alarm value
lower limit 2
Alarm value 3
Alarm value
upper limit 3
Alarm value
lower limit 3
MV monitor
(heat)
MV monitor
(cool)
Press the O and M Keys for at
least 3 s. Display flashess.
Press the O and M Keys
for at least 1 s.
Press the O Key
less than 1 s
Protect Level Communications Setting Level
The time taken to move to the protect level can be
adjusted by changing the "Move to protect level
time" setting.
Starting in automatic
mode.
Process value/
set point
Soak time remain
Displayed only for models with communications.
Changes are effective after cycling power or af-
ter a software reset.
Move to protect level
Displayed only when a
password is set. Restricts
moving to protect level.
Operation/adjustment protect
Restricts displaying and modi-
fying menus in operation, ad-
justment, and manual control
levels.
Initial setting/communications
protect
This protect level restricts
movement to the initial setting,
communications setting, and
advanced function setting lev-
els.
Setting change protect
Protects changes to setups by
operating the front panel keys.
Parameter mask enable
Displayed only when a param-
eter mask is set.
Password to move to protect
level
Password setting
Protocol selection
Switches between CompoWay/F
(SYSWAY) and Modbus.
Communications Unit No.
Communications baud rate
CompoWay/F
(SYSWAY) only
Communications stop bits
Communications parity
Send data wait time
Set point during SP
ramp
Communications
data length
Parameter Flow
This section describes the parameters set in each
level. Pressing the M key at the last parameter in
each level returns to the top parameter in that level.