User Manual

160
Advanced Function Setting Level Section 5-7
Note Event inputs can be used on E5@N-@@@B@ Controllers. Turn the event
inputs ON or OFF while the power is turned ON. Event input ON/OFF
changes are detected for inputs of 50 ms or longer.
Related Parameters
SP 0 to SP 3 (adjustment level): Page 136
Event input assignment 1, Event input assignment 2: Page 160, Multi-SP
uses: Page 160 (advanced function setting level)
The following functions are assigned for event input 1 and event input 2.
RUN/STOP
Auto/manual switch
Program start
Defaults:Event input assignment 1: none
Event input assignment 2: stop
Note This parameter can be set when the program pattern is not set to OFF.
Related Parameters
SP 0 to SP 3 (adjustment level): Page 136,
Number of multi-SP uses (advanced function setting level): Page 159
This parameter enables switching between set points 0 to 3 by operating the
keys on the front panel.
Prerequisites
A model without event inputs
The “number of multi-SP uses” parameter set to 0 on a model with event
inputs
on: Set points 0 to 3 can be selected.
off: Set points 0 to 3 cannot be selected.
Default : OFF
OFF ON Set point 2
ON ON Set point 3
Event input 1 Event input 2 Selected set point
See
See
ev-1 Event Input Assignment 1
Event inputs must be supported.
The “number of multi-SP uses”
parameter must be set to 0 or 1.
ev-2 Event Input Assignment 2
Settings Function
none None
stop RUN/STOP
manu Auto/manual switch
prst Program start (See note.)
Function
Setting
See
See
mspu Multi-SP Uses
The model must not support event
inputs, or the number of multi-SP
uses must be 0.
Function
Setting