Datasheet
 E5@C/E5@C-T
100
stb
0.00
psps
0
p
8.0
i
233
wt-b
off
ins
0.0
inrt
1.000
d
40
c-p
8.0
c-i
233
M
c-d
40
l.adj
1234
at
off
cmwt
off
spmd
psp
fsp
0
M
Adjustment Level 
Display
Displayed only once 
when entering 
Adjustment Level.
AT Execute/Cancel
Communications 
Writing
SP Mode
Fixed SP
PV Input Shift
PV Input Slope 
Coefficient
Wait Band
Standby Time
Program SP Shift Value
Proportional Band
Integral Time
Derivative Time
Proportional Band (Cooling)
Integral Time (Cooling)
Derivative Time (Cooling)
c-db
0.0
Dead Band
ct1
0.0
hb1
0.0
M
Heater Current 1 to 2 
Value Monitor
Heater Burnout 
Detection 1 to 2
lcr1
0.0
hs1
50.0
M
Leakage Current 1 to 2 
Value Monitor 
HS Alarm 1 to 2
Adjustment Level
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
rpt
0
link
end
M
pid
1
M
PID Set No.
Display Segment Selection
END or 0 to Number of segments used − 1
d.seg
end
U
Display Program 
Selection
Press the U Key 
for at least 1 s in 
Program SP Mode.
Number of 
Segments Used
For end
Program 
Repetitions
Program 
Link 
Destination
Process Value/Set 
Point 1 or Process 
Value/Set Point 2 in 
Operation Level
s-no
8
M
7
6
5
4
3
2
1
d.prg
0
D
7
6
5
4
3
2
1
d.seg
0
al1l
0
al-1
0
al1h
0
M
M
Alarm Value 
1 to 4
Alarm 
Upper Limit 
1 to 4
Alarm 
Lower Limit 
1 to 4
of1
0.00
M
ts1s
0
on1
0.00
M
M
Time Signal 1 to 2 
Set Segment
Time Signal 1 to 2 
ON Time
Time Signal 1 to 2 
OFF Time
25
0
U
D
U
D
Program Setting Level
styp
ramp
Segment n Format
sp
0
Segment n SP
pr
0
Segment n Slope
time
0.00
Segment n Time
M
M
For 0 to 7
M
M
M
M
M
M
M
1.c-d
40
1.cdb
0.0
1.ofr
s0.0
1.olh
100.0
1.oll
0.0
1.aut
1320
1.lba
0
M
1.p
8.0
1.i
233
1.d
40
1.c-p
8.0
1.c-i
233
PID 1 
Proportional 
Band
PID 1 Integral 
Time
PID 1 
Derivative Time
PID 1 
Proportional 
Band (Cooling)
PID 1 Integral 
Time (Cooling)
PID 1 
Derivative Time 
(Cooling)
PID 1 Dead 
Band
PID 1 Manual 
Reset Value
PID 1 MV Upper 
Limit
PID 1 MV Lower 
Limit
PID 1 Automatic 
Selection Range 
Upper Limit
PID 1 LBA 
Detection 
Time
M
M
PID Setting Level
M
M
M
M
M
M
M
M
M
M
Display PID 
Selection
8
7
6
5
4
3
2
d.pid
1
U
D
hold
off
ct1
0.0
pgsg
0.00
prg
0
a-m
lcr1
0.0
o
0.0
c-o
0.0
r-r
rst
25
0
25
0
v-m
0.0
M
seg
0
stbm
0.00
prgt
0.00
rptm
0
Process 
Value/Set Point 1
Process 
Value/Set Point 2
Auto/Manual Switch
Program No. Monitor/
Segment No. Monitor
Program Number
Hold
Segment Number
Remaining 
Standby Time 
Monitor
Heater Current 1 to 
2 Value Monitor
Leakage Current 1 
to 2 Value Monitor
MV Monitor 
(Heating)
MV Monitor 
(Cooling)
Valve Opening 
Monitor
Elapsed 
Program Time 
Monitor
Program Execution 
Repetitions Monitor
Run/Reset 
(of the program)
Operation Level
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
25
50.0
PV/Manual MV
Manual Control Level
Press O Key for 
at least 3 s while 
a-m is displayed.
Press O or S 
Key for at least 
1 s.
*1
Press S 
Key for at 
least 1 s.
*1
S
* The monitor/setting items to display are set in the Monitor/Setting Item 1 to 5 parameters 
 (Advanced Function Setting Level).
PF Monitor/Setting 
Item display 2 to 5
Monitor/Setting Item Level
 25
0
PF Monitor/
Setting Item 
display 1
Press O Key for less than 1 s.
Press O Key for less than 1 s.
Press S Key.
*2
Press S Key.
*2
Starting in manual mode
Power ON
Press O 
Key for 
less than 
1 s.
Press O 
Key for less 
than 1 s.
E5@C-T
Some parameters may not be displayed depending on the model and other settings.