Datasheet
A-449E3X-NA
E3X-NA
Dimensions (Unit: mm)
Amplifier Units
P
re-w
i
re
d
E3X-NA11
E3X-NA11F
E3X-NA41
E3X-NA41F
E3X-NAG11
E3X-NAG41
8
10.7
Two, 2.4 dia.
10
3
64.3
38.6
31.5
9.9
5.3
Holes for optical communications * 2
3.4
22.4 16
4.4
4.1
13
34.8
2.4
22.4
16
4
Two, 3.2 dia. holes Mounting bracket (E39-L143); Sold separately
Stainless steel (SUS304)
10.75
(A)*1
Note: * 1. The mounting bracket can also be used on side A.
* 2. The hole for optical communications is for
preventing mutual interference. There is no
hole for E3X-NA
#F models.
16
Mounting Holes
2-M3
Operation indicator
15.75
9.2
13.05
Incident level indicators
4-dia., 3-conductor,
vinyl-insulated round cable
(conductor cross-sectional
area: 0.45 m‡u; insulation
diameter: 1.1 mm)
With Mounting Blanket Attached
With Mounting Blanket Attached
9.2
28.65
25.95
(A)*1
12
8
10.7
Two, 2.4 dia.
4.3
9.9
3.43.9
33
Holes for
optical
communications
Mounting bracket (E39-L148); Sold separately
Stainless steel (SUS304)
23.9
14.4
11.5
67.2
37
16
16
23.9
6.6
11.2
2.8
* 2
40
5.4
5.4
3.4
3.4
16
2-M3
4-dia., 3-conductor, vinyl-insulated round cable
(conductor cross-sectional area: 0.45 mm²;
insulation diameter: 1.1 mm)
Note:*1.The mounting bracket can also be used on side A.
*2.
Mounting Holes
6.9
81.5
Operation indicator
Incident level indicators
Amplifier Units with cables,
Water-resistant Models
E3X-NA11V
E3X-NA41V