Datasheet

If stable operation is not possible near a mirror surface, mount the
Sensor at an angle as shown below, and separate the Sensor as far
as possible from the mirror surface.
Detected object
Mirror surface
Mount the Sensor so that it is not aligned with the direction of move-
ment of the detected object, as shown below.
Mount the Sensor so that it is not aligned with extreme changes in
color or materials, as shown below.
Direction of
movement
Direction of
movement
Correct Incorrect
Detected
object
Detected
object
Detected
object
Direction of
movement
Direction of
movement
Correct
Incorrect
Mount the Sensor so that sunlight, fluorescent light, incandescent
light, or other strong sources of light do not enter the directional
angle of the Sensor.
Precautions
When mounting the Sensor, do not hit the Sensor with a hammer, or
any other object. This will cause the Sensor to lose its watertight-
ness.
Use M4 screws to mount the Sensor.
The tightening torque of each screw must be 12 kgf
m (1.18 N
m)
maximum.
Direct Mounting
Mount the Sensor as shown in the following illustration.
M4 hole
M4 hole
Two, 4.5 dia.
through holes
Two, M3
WARNING
The E3S-CL is not a safety component for ensuring the safety
of people which is defined in EC directive (91/368/EEC) and
covered by separate European standards or by any other reg-
ulations or standards.
Cat. No. CEDSAX2 3/97 Specifications subject to change without notice. Printed in U.S.A.
OMRON ELECTRONICS, INC.
One East Commerce Drive
Schaumburg, IL 60173
NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4.
1-800-55-OMRON
OMRON CANADA, INC.
885 Milner Avenue
Scarborough, Ontario M1B 5V
8
416-286-6465
E3S-CL E3S-CL
!