Datasheet

Detection distance (mm)
Material
(Setting Distance Set to 100 mm using
White Paper)
(Setting Distance Set to 40 mm using
White Paper)
Material Material
Detection distance (mm)
Detection distance (mm)
Plywood
White paper
Black paper
Black rubber
Cardboard
Mirror
Plywood
White paper
Black paper
Black rubber
Cardboard
Mirror
Plywood
White paper
Black paper
Black rubber
Cardboard
Mirror
E3S-CL2
(Setting Distance Set to 500 mm using
White Paper)
Detection distance (mm)
Material
(Setting Distance Set to 300 mm using
White Paper)
(Setting Distance Set to 50 mm using
White Paper)
Material Material
Detection distance (mm)
Detection distance (mm)
White paper
Plywood
Cardboard
Black paper
Black rubber
Mirror
White paper
Plywood
Cardboard
Black paper
Black rubber
Mirror
White paper
Plywood
Cardboard
Black paper
Black rubber
Mirror
(Setting Distance Set to 200 mm
using White Paper)
E3S-CL1
DETECTION DISTANCE VS. MATERIAL
Nomenclature
Cover
Output switch
Mode switch
Light indicator (orange)
Distance setting indicator
Distance setting knob
Output Switch
1. Set the switch to NPN for NPN output.
2. Set the switch to PNP for PNP output.
Mode Switch
1. Set the switch to L-ON for ON light-ON operation.
2. Set the switch to D-ON for ON dark-ON operation.
Distance Setting Knob
1. The detection distance will increase when the knob is
turned clockwise (toward Max.) andwill decrease whenthe
knob is turned counterclockwise.
2. The adjustment can be turned up to 6 times clockwise or
counterclockwise to set the detection distance. The num-
ber of turns will be displayed by the indicator.
Stability indicator
(green)