Datasheet

7
E3FA/E3RA/E3FB/E3RB
Straight type (E3FA/E3FB)
* IP69K Degree of Protection Specifications
IP69K is a protection specification stipulated by DIN 40050 Part 9 of the German standards.
The test item is sprayed with 80°C water from a nozzle of a specified shape at a water pressure of 80 to 100 bar. The amount of water
is 14 to 16 liters per minute.
The distance between the test item and the nozzle is 10 to 15 cm. The water is discharged at angles of 0°, 30°, 60°, and 90° from
the horizontal plane for 30 seconds at each angle while the test item is rotated horizontally.
Sensing method Diffuse-reflective
Model
NPN
output
Pre-wired
E3F
@
-DN11 2M E3F
@
-DN12 2M E3F
@
-DN13 2M E3FA-DN14 2M E3FA-DN15 2M E3FA-DN16 2M
M12 Connector
E3F@-DN21 E3F@-DN22 E3F@-DN23 E3F
A
-DN24 E3F
A
-DN25 E3F
A
-DN26
PNP
output
Pre-wired
E3F
@
-DP11 2M E3F
@
-DP12 2M E3F
@
-DP13 2M E3FA-DP14 2M E3FA-DP15 2M E3FA-DP16 2M
Item
M12 Connector
E3F@-DP21 E3F@-DP22 E3F@-DP23 E3F
A
-DP24 E3F
A
-DP25 E3F
A
-DP26
Sensing distance
100 mm
(white paper:
300 × 300 mm)
300 mm
(white paper:
300 × 300 mm)
1 m
(white paper:
300 × 300 mm)
100 mm
(white paper:
300 × 300 mm)
300 mm
(white paper:
300 × 300 mm)
1 m
(white paper:
300 × 300 mm)
Spot diameter (reference value)
40
×
45 mm
Sensing distance
of 100 mm
40
×
50 mm
Sensing distance
of 300 mm
120
×
150 mm
Sensing distance
of 1 m
40
×
45 mm
Sensing distance
of 100 mm
40
×
50 mm
Sensing distance
of 300 mm
120
×
150 mm
Sensing distance
of 1 m
Standard sensing object
Differential travel 20% max.
Directional angle
Light source (wavelength) Red LED (624 nm)
Infrared LED (850 nm)
Power supply voltage 10 to 30 VDC (include voltage ripple of 10%(p-p) max.)
Current consumption 25 mA max.
Control output
NPN/PNP (open collector)
Load current: 100 mA max. (Residual voltage: 3 V max.), Load power supply voltage: 30 VDC max.
Operation mode Light-ON/Dark-ON selectable by wiring
Indicator
Operation indicator (orange)
Stability indicator (green)
Protection circuits
Power supply reverse polarity protection, Output short-circuit protection, and Output reverse polarity protection
Response time 0.5 ms
Sensitivity adjustment One-turn adjuster
Ambient illumination (Receiver side)
Incandescent lamp: 3,000 lx max./ Sunlight: 10,000 lx max.
Ambient temperature range Operating: -25 to 55
°
C/ Storage: -30 to 70
°
C (with no icing or condensation)
Ambient humidity range Operating: 35 to 85%/ Storage: 35 to 95% (with no condensation)
Insulation resistance 20 MΩ min. at 500 VDC
Dielectric strength 1,000 VAC at 50/60 Hz for 1 min. between current-carrying parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5 mm double amplitude for 2 hours each in X, Y and Z directions
Shock resistance Destruction: 500 m/s
2
3 times each in X, Y and Z directions
Degree of protection IEC: IP67, DIN 40050-9: IP69K *
Weight
(packed
state/only
sensor)
Pre-wired cable (2M)
E3FA: Approx. 60 g/ Approx. 50 g,
E3FB: Approx. 95 g/ Approx. 65 g
Connector
E3FA: Approx. 20 g/ Approx. 10 g,
E3FB: Approx. 50 g/ Approx. 20 g
Material
Case E3FA: ABS, E3FB: Nickel-brass
Lens and Display PMMA
Adjuster POM
Nut E3FA: POM, E3FB: Nickel-brass
Accessories
Instruction sheet
M18 nuts (2 pcs)