Amplifiers – easy usage
E3X-HD
Fiber amplifier
Easy-teach digital fiber amplifier
The E3X-HD with 1-button Smart tune set-up provides fast and simple teaching. Dual
digital display and advanced features make the E3X-HD ideal even for demanding
applications.
• Easy teaching by Smart tuning within a few seconds
• Dynamic Power Control (DPC) for highest operational stability for changing
environmental conditions or challenging objects
• High signal resolution - 2.5 times higher compared to conventional models
• EtherCAT and CompoNet Communication units for high-speed field bus
connectivity
Ordering information
Fiber amplifier connectors
Communication units
Specifications
Item Order code
Transistor output models Communication unit model
*1
*1
For field bus connection please chose Communication unit E3X-ECT for EtherCAT or E3X-CRT for CompoNet.
NPN output PNP output
Pre-wired E3X-HD11 2M E3X-HD41 2M –
Fiber amplifier connector E3X-HD6 E3X-HD8 E3X-HD0
Shape Type Comment Order code
Fiber amplifier connector 2 m PVC cable E3X-CN11
30 cm PVC cable with M12 plug connector (4 pin) E3X-CN21-M1J 0.3M
30 cm PVC cable with M8 plug connector (4 pin) E3X-CN21-M3J-2 0.3M
Shape Communications method Applicable Fiber Amplifier Units Order code
CompoNet E3X-HD0
E3X-MDA0
E3X-DA0-S
E3X-CRT
EtherCAT E3X-ECT
Item
Type Standard models For Communications Unit
Model E3X-HD11 E3X-HD41 E3X-HD6 E3X-HD8 E3X-HD0
Connection method Pre-wired Wire-saving connector Communications unit
connector
Control output NPN output PNP output NPN output PNP output –
Light source (wavelength) Red, 4-element LED (625 nm)
Power supply voltage 12 to 24 VDC ±10%, ripple (p-p)10% max.
Power consumption Normal Mode: 720 mW max. (Current consumption: 30 mA max. at 24 VDC, 60 mA max. at 12 VDC.)
Power Saving Eco Mode: 530 mW max. (Current consumption: 22 mA max. at 24 VDC, 44 mA max. at 12 VDC.)
Control output Load power supply voltage: 26.4 VDC max., open-collector output (Varies with the model depending on
output is PNP or NPN.)Load current: 50 mA max. (residual voltage: 2 V max.), OFF current: 0.5 mA max.
–
Response time
Super-high-speed Mode
(SHS)
Operate or reset: 50 μs Operate or reset: 55 μs Operate or reset: 50 μs Operate or reset: 55 μs Operate or reset: 50 μs
High-speed Mode (HS) Operate or reset: 250 μs
Standard Mode (STND) Operate or reset: 1 ms
Giga-power Mode (GIGA) Operate or reset: 1 ms
Mutual interference
prevention
Possible for up to 10 units
Maximum
connectable Units
16 units with E3X-CRT: 16 units