Designing
Power
Supply
A
power supply with full-wave rectification can be connected to the
E3G-ML79(T).
Wiring
The
tensile strength of the cable during operation should not exceed
the
values shown below
.
Model
T
ensile strength (torque)
E3G-L73, E3G-ML79(T) 50 N max.
E3G-L77
10 N max.
Mounting
Mounting Directions
Make sure that the sensing side of the Sensor is parallel with the
surface
of each sensing
object. Do not incline the Sensor towards
the sensing object.
Sensing side
Surface of sensing object
If
the sensing object has a glossy surface, incline the Sensor by 5
°
to
10°
as shown below, provided that the Sensor is not influenced by
any
background objects.
Glossy object
If there is a mirror-like object below the Sensor
, the Sensor may not
be in stable operation. Therefore, incline the Sensor or keep the
Sensor
a distance away from the mirror-like object as shown
below
.
Sensing object
Mirror-like object
Make
sure not to
install the Sensor in the incorrect direction. Refer to
the
following.
Sensing
object
Moving direction
Moving direction
Sensing
object
Sensing
object
Moving direction
Correct Correct Incorrect
Install
the Sensor as shown in the following if
each sensing object
greatly dif
fers in color or material.
Moving direction
Moving direction
Correct Incorrect
Others
If
a teaching data error occurs with the
operation indicator flashing
due
to a power failure or static noise, perform the teaching operation
of
the Sensor again.