Datasheet
254
E3X-DA-AT-S
Fiber amplifier
Digital fiber amplifier with active threshold
control for dust and dirt compensation
The active threshold E3X-DA-AT-S digital fiber amplifier compensates for light power
reduction caused by dirt and ensures stable operation.
• Active threshold control for high stability
• Alarm output for maintenance warning
• Area detection function for quality inspection or sensing range control
Ordering information
Specifications
Timing diagram of signal changes with and without ATC
Fiber amplifier connectors
Item Functions Order code
NPN output PNP output
Pre-wired version ATC (active threshold control)
ATC error alarm output
E3X-DA11AT-S E3X-DA41AT-S
Connector version
*1
*1
Order connector separately.
E3X-DA6AT-S E3X-DA8AT-S
Item NPN output E3X-DA11AT-S E3X-DA6AT-S
PNP output E3X-DA41AT-S E3X-DA8AT-S
Light source (wave length) Red LED (650 nm)
Power supply voltage 12 to 24 VDC ±10%, ripple (p-p): 10% max.
Protective circuits Power supply reverse polarity protection, output short circuit protection, mutual interference prevention
Response
time
Super-high-speed
mode
Operation or reset: 80 μs
High-speed mode Operation or reset: 250 μs
Standard mode Operation or reset: 1 ms
High-resolution mode Operation or reset: 4 ms
Sensitivity setting Teaching and digital up/down keys
Functions ATC Active threshold control (used for output 1)
I/O settings Used for output 1: ATC error alarm output
Startup operation The operation when power is turned ON can be selected: no operation, power tuning or power tuning + ATC
Digital display Incident level + threshold or user specific
Shape Type Comment Order code
Fiber amplifier
connector
2 m PVC cable E3X-CN21
30 cm PVC cable with M12 plug connector (4 pin) E3X-CN21-M1J 0.3M
30 cm PVC cable with M8 plug connector (4 pin) E3X-CN21-M3J-2 0.3M
T/ms
Output V Received light
Sensor output
Threshold
without ATC
Incident level
ATC threshold
Without ATC: malfunction caused by
temperature drift, pollution or condensation
Operation with ATC
Operation without ATC