Brochure

6
Selection table
Fiber sensor heads
Note: All sensing distances measured with E3X-DA-SE-S. Longer sensing distances up to 80% can be achieved with E3X-DA-S.
Fiber amplifiers
Type Cylindrical Square shape Miniature Longer distance Chemical resistant
Model E32 standard cylindrical E32 square shape E32 miniature E32 longer distance E32 chemical resistant
Key features Standard and high-flex
fibers
Sizes M3 to M6
3 or 4 mm thin housing
•Models in X,Y or Z-axis
Direct mounting without
bracket
•Sizes from dia 500µm to
3mm
Bendable sleeves
Built in focal lenses Fluoroplastic cover or
coating
Through-beam 1,550 mm 1,550 mm 1,550 mm 20 m 4 m
Retro-reflective 250 mm 1.5 m
Diffuse-reflective 650 mm 600 mm 600 mm 1.4 m 350 mm
Page 8 10 12 14 16
Type Easy teach/double display Easy teach/single display Potentiometer adjuster High performance Double amplifier
Model E3X-HD E3X-SD E3X-NA E3NX-FA E3X-MDA
361° PRO LITE LITE PRO
plus
n.a.
Key features Easy operation by
smart tuning
•Dynamic power control
Fieldbus connectivity
1 button object teaching
Auto teach during operation
Easy adjustment by
potentiometer
High functionality signal
processing (timer, counter,
dynamic power control, etc.
High signal resolution
Increased sensing distance
Double output/external
input
•Fieldbus connectivity
2 inputs and AND, OR signal
comparison
Response time (min.) 1 ms
(50 s in super-high-speed
mode)
1 ms 200 µs 1 ms
(30 µs in super-high-speed
mode)
1 ms
(130 µs in high speed mode)
Page 27 30 31 32 35