Brochure
E3NX-FA Fiber amplifier
34
Easy One-Button-Teaching/Smart Tuning
Easy setting of optimum power and threshold by pushing tune button twice.
Smart power control
Enhanced signal stability control for compensating power reductions caused by temperature drift, dust or aging of LED. Alarm output added for predictive maintenance.
N-Smart platform
The N-Smart platform provides wide portfolio of advanced sensors – all with the
same intuitive operation concept and field bus connectivity.
5000
9999
Automatic setting of optimum values
ST
Dynamic range
increased by a
factor of 40,000
Press the button
once with a workpiece and
once without a workpiece
TUNE
Set to the intermediate
value between
the incident levels with and
without a workpiece.
Incident level
adjustment with and
without a workpiece
Threshold + Incident level
Without APC
With APC
Light intensity
Time
Long-term stability
Flashes when
compensation is
no longer possible.
Incident level
Target value
(displayed
incident level)
Compen-
sated.
Compen-
sated.
Compen-
sated.
Setting value
(threshold value)
Time
APC
(AUTO POWER
CONTROL)
Automatically
compensate light
intensity
DPC
(DYNAMIC POWER
CONTROL)
Automatically
compensate
incident level
Smart Power
Control
Always ON
DPC