Datasheet

E2Q6
5
Mutual Interference
If more than one Proximity Sensor is installed face-to-face or side-by-
side, make sure that the distances between two units adjacent to each
other are the same as or larger than the corresponding values shown
in the following table.
(Unit: mm)
Tightening Torque
Tighten bolts and screws with the specified torque.
Switching the Sensing Direction
1. Remove two screws.
2. Lifting the sensing surface separates it from the case.
3. When positioning the sensing surface to the side, rotate it to the
required position, then fit it into the case. (The possible positions
are 0, 90, 180, and 270. Do not forcefully rotate the sensing
surface.)
4. Secure it with the screws.
Model A B
E2Q6-N203-H 170 120
E2Q6-N30M3-H 280 200
Between case and terminal 1.8 N·m
Terminal screws 1.0 N·m
A
B
A
(1)
(2)