Datasheet

E2Q6
3
Engineering Data (Reference Value)
I/O Circuit Diagrams
NPN
PNP
Sensing Area
Shielded Models
E2Q6-N203-H
Unshielded Models
E2Q6-N30M3-H
Influence of Sensing Object Size and Materials
Shielded Models
E2Q6-N203-H
Unshielded Models
E2Q6-N30M3-H
Model Operation mode Timing charts Output circuit
E2Q6-N20E3-H
E2Q6-N30ME3-H
NO + NC
Model Operation mode Timing charts Output circuit
E2Q6-N20F3-H
E2Q6-N30MF3-H
NO + NC
Distance Y (mm)
Distance X (mm)
0
5
10
15
20
25
30
35
40 30 20 10 0 10 20 30 40
Sensing Head
X
Y
Distance Y (mm)
Distance X (mm)
0
5
10
15
20
25
30
35
40 30 20 10 0 10 20 30 40
Sensing Head
X
Y
Side length of sensing object: d (mm)
Iron
Brass
Distance X (mm)
010203040506070
5
0
10
15
20
25
X
Stainless steel
SUS304
Aluminum
Copper
d
t = 1 mm
Iron
Brass
Distance X (mm)
Side length of sensing object: d (mm)
010203040506070
5
0
15
10
20
30
25
35
X
Aluminum
Copper
Stainless steel
SUS304
d
t = 1 mm
Sensing
object
Sensing areaOutside of sensing area
Proximity
Sensor
Lit
Not lit
ON
OFF
ON
OFF
Detection indicator
(yellow)
Control output, NO
Control output, NC
(%)
100 0
Rated sensing distance
1
4
2
3
+V
Terminal arrangement
Cable connecting side
Load
Load
Proximity
Sensor
main
circuit
0 V
NO output
NC output
Lit
Not lit
ON
OFF
ON
OFF
Sensing
object
Proximity
Sensor
Sensing area
Outside of sensing area
Detection indicator
(yellow)
Control output, NO
Control output, NC
(%)
100 0
Rated sensing distance
0 V
NO output
NC output
+V
1
4
2
3
Proximity
Sensor
main
circuit
Load Load
Terminal arrangement
Cable connecting side