E2K-C
AC 2-Wire Models
AC/DC 2-Wire Models
Operation
mode
Model Timing chart Output circuit
NO E2K-C25MY1
NC E2K-C25MY2
Operation
mode
Model Timing chart Output circuit
NO E2K-C20MT1
NC E2K-C20MT2
Present
Not present
Operate
Reset
ON
OFF
Load
Operation
indicator (red)
Sensing
object
Brown
Blue
Load
Proximity
Sensor
main
circuit
Present
Not present
Operate
Reset
ON
OFF
Load
Operation
indicator (red)
Sensing
object
Sensing
object
Operation
indicator (yellow)
Load
Present
Not present
Operate
Reset
ON
OFF
24 to 240 VAC
24 to 240 VDC
0 V
Brown*
Blue
Load
* Load current: 200 mA max.
Proximity
Sensor
main
circuit
Present
Not present
Operate
Reset
ON
OFF
Load
Operation
indicator (yellow)
Sensing