Datasheet
3E2FQ
Output Circuit Diagram
Precautions
Design
Effects of Surrounding Metal
Provide a minimum distance between the Sensor and the
surrounding metal as shown in the table below.
Effects of Surrounding Metal (Unit: mm)
Mutual Interference
If more than one Proximity Sensor is installed face to face or
in parallel, ensure that the distances between two Units adja-
cent to each other are the same as or larger than the corre-
sponding values shown in the following table.
Installation
Do not tighten the nut with excessive force. A washer must be
used with the nut.
Note: The table below shows the value of tightening torques when using
toothed washers.
Others
Chemical resistance
Operating
status
Output
specifications
Model Timing chart Output circuit
NO
PNP
E2FQ-X@F1
NPN
E2FQ-X@E1
DC 2-wire
E2FQ-X@D1
Yes
No
Operates
Releases
H
L
Load
(between black
and blue leads)
Output voltage
(between black
and blue leads)
Sensing
object
ON
OFF
Operation
indicator
Brown
Black
Output
Blue
100W
4.7kW
2.2W
Main
circuit
+V
0V
Load
Yes
No
Operates
Releases
H
L
Load
(between black
and blue leads)
Output voltage
(between black
and blue leads)
Sensing
object
ON
OFF
Operation
indicator
Brown
Black
Output
Blue
100W
4.7kW
2.2W
Main
circuit
+V
0V
(see note 2)
(see note 1)
Tr
Note:
1. 200 mA max.(load current)
2. When a transistor is connected
Load
Operation
indicator
Operates
Releases
ON
OFF
Load
Sensing
object
Yes
No
Load
Brown
Blue
Main
circuit
+V
0V
Note:
The load can be connected to
either the +V or the 0-V line.
Correct Use
Model
Item
l d D m n
E2FQ-X2#
0
12
0
818
E2FQ-X5#
18 20 27
E2FQ-X10#
30 40 45
l
m
n
l
m
D
d dia.
Model
Torque Tensile strength
(torque)
E2FQ-X2# 0.98 Nm
E2FQ-X5#
2 Nm
E2FQ-X10#
A
B
Mutual Interference (Unit: mm)
Model
Item
A B
E2FQ-X2#
30 20
E2FQ-X5#
50 35
E2FQ-X10#
100 70