Datasheet

E2EQ
7
Dimensions
Pre-wired Models
Long Sensing-distance Models
Standard Models
(Unit: mm)
Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified.
38 9
2
10
33
17
4
21 dia.
*1
M12 × 1
Indicators *2
Two clamping nuts
Toothed washer
*1. 4-dia. vinyl-insulated round cable with 2 conductors (Flame-resistant,
Conductor cross section: 0.3 mm
2
, Insulator diameter: 1.3 mm),
Standard length: 2 m
The cable can be extended up to 200 m (separate metal conduit).
*2. Operation indicator (red), Setting indicator (green)
E2EQ-X4X1
E2EQ-X8X1
43
12
2
10
38
24
4
29 dia.
*1
M18 × 1
*1. 4-dia. vinyl-insulated round cable with 2 conductors
(Flame-resistant, Conductor cross section: 0.3 mm
2
,
Insulator diameter: 1.3 mm), Standard length: 2 m
The cable can be extended up to 200 m (separate
metal conduit).
*2. Operation indicator (red), Setting indicator (green)
Indicators *2
Two clamping nuts
Toothed washer
48
12
3
10
43
36
5
42 dia.
*1
M30 × 1.5
*1. 6-dia. vinyl-insulated round cable with 2 conductors (Flame-resistant,
Conductor cross section: 0.5 mm
2
, Insulator diameter: 1.9 mm),
Standard length: 2 m
The cable can be extended up to 200 m (separate metal conduit).
*2. Operation indicator (red), Setting indicator (green)
Indicators *2
Two clamping nuts
Toothed washer
E2EQ-X15X1
38
27.6
24
21 dia.
17
5
M12 × 1
4
Two toothed washers
Indicators *2
*1
Two clamping nuts (fluororesin coated)
*1. 6-dia. vinyl-insulated round cable with 2 conductors
(Flame-resistant, Conductor cross section: 0.5 mm
2
,
Insulator diameter: 1.9 mm), Standard length: 2 m
The cable can be extended up to 200 m (separate metal
conduit).
*2. Operation indicator (red), Setting indicator (green)
E2EQ-X3D1
47
32
29
6
29 dia.
24
M18 × 1
4
*1
Two toothed washers
Indicators *2
Two clamping nuts (fluororesin coated)
*1. 6-dia. vinyl-insulated round cable with 2 conductors
(Flame-resistant, Conductor cross section: 0.5 mm
2
,
Insulator diameter: 1.9 mm), Standard length: 2 m
The cable can be extended up to 200 m (separate metal
conduit).
*2. Operation indicator (red), Setting indicator (green)
E2EQ-X7D1
56
42
38
36
42 dia.
10
*1
M30 × 1.5
5
Two toothed washers
Indicators *2
Two clamping nuts (fluororesin coated)
*1. 6-dia. vinyl-insulated round cable with 2 conductors (Flame-resistant,
Conductor cross section: 0.5 mm
2
, Insulator diameter: 1.9 mm),
Standard length: 2 m
The cable can be extended up to 200 m (separate metal conduit).
*2. Operation indicator (red), Setting indicator (green)
E2EQ-X10D1