E2EH-X@C@/B@ DC 3-Wire Models
*1. The response frequency is an average value.
Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance.
*2. Operation with power supplied for 1,000 h has been verified at 120°C. Do not bend the cable repeatedly at 100°C or higher.
Size M12 M18 M30
Shielded Shielded
Item Model E2EH-X3C@/B@ E2EH-X7C@/B@ E2EH-X12C@/B@
Sensing distance 3 mm±10% 7 mm±10% 12 mm±10%
Set distance *1 0 to 2.4 mm 0 to 5.6 mm 0 to 9.6 mm
Differential travel 15% max. of sensing distance
Detectable object
Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering
Data (Reference Value) on page 6.)
Standard sensing object Iron, 12 × 12 × 1 mm Iron 21 × 21 × 1 mm Iron 36 × 36 × 1 mm
Response frequency *2 500 Hz 300 Hz 100 Hz
Power supply voltage (operating
voltage range)
12 to 24 VDC, ripple (p-p): 10% max.
(10 to 32 VDC, however, 24 VDC max. at temperatures over 100°C)
Current consumption 10 mA max.
Control out-
put
Load current 100 mA max. (however, 50 mA max. at 100 to 120°C)
Residual voltage 2 V max. (Load current: 100 mA, Cable length 2 m)
Indicators Operation indicator (yellow)
Operating mode
(with sensing object approaching)
C1 Models: NO
C2 Models: NC
B1 Models: NO
B2 Models: NC
Protection circuits
Power supply reverse polarity protection, Surge suppressor, Load short-circuit protection,
Reversed output polarity protection
Ambient temperature range
Operating: 0 to 100°C (0 to 120°C 1,000 h) *2
Storage: −25 to 70°C (with no icing or condensation)
Ambient humidity range 35% to 95%
Temperature influence
±10% max. of sensing distance at 23°C in the temperature range of 0 to 70°C.
±15% max. of sensing distance at 23°C in the temperature range of 70 to 100°C.
−15% to 20% of sensing distance at 23°C in the temperature range of 100 to 120°C.
Voltage influence 10% max. of sensing distance at rated voltage in the 15% rated voltage range.
Insulation resistance 50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 1,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case
Vibration resistance Destruction: 10 to 55 Hz 1.5-mm double amplitude for 2 hours each in X, Y and Z directions
Shock resistance Destruction: 1,000 m/s
2
, 10 times each in X, Y and Z directions
Degree of protection IEC IP67, DIN 40050-9 IP69K
Connection method Pre-wired Models (Standard cable length 2 m), Connector Models
Weight
(packed state)
Pre-wired Models Approx. 80 g Approx. 145 g Approx. 220 g
Connector Models Approx. 30 g Approx. 55 g Approx. 125 g
Materials
Case, clamping nut Stainless steel (SUS316L)
Sensing surface PBT
Cable Heat-resistant PVC cable (Pre-wired Model)
Accessories Instruction manual