Datasheet

3
E2EH
Ratings and Specifications
E2EH-X@D@ DC 2-Wire Models
*1. Use the yellow indicator on D1 Models as a guide.
*2. The response frequency is an average value.
Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance.
*3. The residual voltage of each E2EH-X@D@ DC 2-Wire Model is 5 V. When connecting to a device, make sure that the device can withstand the residual voltage.
(Refer to page 9.)
*4. Operation with power supplied for 1,000 h has been verified at 110°C. Do not bend the cable repeatedly at 100°C or higher.
*5. IP69K Degree of Protection Specification
IP69K is a protection standard against high temperature and high-pressure water defined in the German standard DIN 40050,
Part 9. The test piece is sprayed with water at 80°C at a water pressure of 80 to 100 BAR using a specified nozzle shape at a
rate of 14 to 16 liters/min.
The distance between the test piece and nozzle is 10 to 15 cm, and water is sprayed horizontally for 30 seconds each at 0°,
30°, 60°, and 90° while rotating the test piece on a horizontal plane.
Size M12 M18 M30
Shielded Shielded
Item Model E2EH-X3D@ E2EH-X7D@ E2EH-X12D@
Sensing distance 3 mm 7 mm 12 mm
Set distance *1 0 to 2.4 mm 0 to 5.6 mm 0 to 9.6 mm
Differential travel 15% max. of sensing distance
Detectable object
Ferrous metal (The sensing distance decreases with non-ferrous metal.
Refer to Engineering Data (Reference Value) on page 6.)
Standard sensing object Iron, 12 × 12 × 1 mm Iron 21 × 21 × 1 mm Iron 36 × 36 × 1 mm
Response frequency *2 500 Hz 300 Hz 100 Hz
Power supply voltage (operating
voltage range)
12 to 24 VDC, ripple (p-p): 10% max.
(10 to 32 VDC, however, 24 VDC max. at temperatures over 100°C)
Leakage current 0.8 mA max.
Control out-
put
Load current 3 to 100 mA (however, 3 to 50 mA at 100 to 110°C)
Residual voltage *3
Polarity Models: 3 V max.
No polarity Models: E2EH-X@D@-T: (5 V max. *3 (Load current: 100 mA, Cable length 2 m)
Indicators
D1 Models: Operation indicator (red), Setting indicator (yellow)
D2 Models: Operation indicator (yellow)
Operation mode (with sensing ob-
ject approaching)
D1 Models: NO
D2 Models: NC
Protection circuits Surge suppressor, Load short-circuit protection
Ambient temperature range
Operating: 0 to 100°C (0 to 110°C 1,000 h) *4
Storage: 25 to 70° (with no icing or condensation)
Ambient humidity range 35% to 95%
Temperature influence
±10% max. of sensing distance at 23°C in the temperature range of 0 to 70°C.
±15% max. of sensing distance at 23°C in the temperature range of 70 to 100°C.
15% to +20% of sensing distance at 23°C in the temperature range of 100 to 110°C.
Voltage influence ±10% max. of sensing distance at rated voltage in the 15% rated voltage range.
Insulation resistance 50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 1,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case
Vibration resistance Destruction: 10 to 55 Hz 1.5-mm double amplitude for 2 hours each in X, Y and Z directions
Shock resistance Destruction: 1,000 m/s
2
, 10 times each in X, Y and Z directions
Degree of protection IEC IP67, DIN 40050-9 IP69K *5
Connection method Pre-wired Models (Standard cable length 2 m), Connector Models
Weight
(packed state)
Pre-wired Models Approx. 80 g Approx. 145 g Approx. 220 g
Connector Models Approx. 30 g Approx. 55 g Approx. 125 g
Materials
Case, clamping nut Stainless steel (SUS316L)
Sensing surface PBT
Cable Heat-resistant PVC cable (Pre-wired model)
Accessories Instruction manual
Refer to the timing charts under I/O Circuit Diagrams on page 7 for details.