Datasheet

E2E2-X
C
/B
DC 3-wire Models
Part number E2E2-X2C
/
B
E2E2-X5MC
/
B
E2E2-X5C
/
B
E2E2-X10MC
/B
E2E2-X10C
/
B
E2E2-X18MC
/B
Size M12 M18 M30
Type Shielded Unshielded Shielded Unshielded Shielded Unshielded
Sensing distance 2 mm (0.08 in)
±10%
5 mm (0.20 in)
±10%
5 mm (0.20 in)
±10%
10 mm (0.39
in) ±10%
10 mm (0.39
in) ±10%
18 mm (0.71
in) ±10%
Supply voltage (operating
voltage range)
12 to 24 VDC, ripple (p-p): 10% max., (10 to 55 VDC)
Current consumption 13 mA max.
Sensing object Magnetic metals (refer to
Engineering Data
for non-magnetic metals)
Setting distance 0to1.6mm
(0 to 0.06 in)
0to4.0mm
(0 to 0.16 in)
0to4.0mm
(0 to 0.16 in)
0to8.0mm
(0 to 0.31 in)
0to8.0mm
(0 to 0.31 in)
0 to 14.0 mm
(0 to 0.55 in)
Standard object (mild steel) 12 x 12 x
1 mm (0.47 x
0.47 x 0.04 in)
15x15x1mm
(0.59 x 0.59 x
0.04 in)
18 x 18 x
1 mm (0.71 x
0.71 x 0.04 in)
30 x 30 x
1 mm (1.18 x
1.18 x 0.04 in)
30 x 30 x
1 mm (1.18 x
1.18 x 0.04 in)
54 x 54 x
1 mm (2.13 x
2.13 x 0.04 in)
Differential travel 10% max. of sensing distance
Response frequency 1.5 kHz 0.4 kHz 0.6 kHz 0.2 kHz 0.4 kHz 0.1 kHz
Operation (with sensing object
approaching)
B1/C1 models: Load ON
B2/C2 models: Load OFF
Control output (switching
capacity)
200 mA max., open collector
Circuit protection Reverse connection protection, surge absorber, load short-circuit protection
Indicator Operation indicator (red LED)
Ambient temperature Operating: --40°Cto85°Cwithnoicing(--40°F to 185°F)
Ambient humidity Operating: 35% to 95%
Temperature influence ±15% max. of sensing distance at 23°C in temperature range of --40°Cto85°C(--40°F to 185°F)
±10% max. of sensing distance at 23°C in temperature range of --25°Cto70°C(--13°F to 158°F)
Voltage influence ±1% max. of sensing distance in rated voltage range ±15%
Residual voltage 2.0 V max. (under load current of 200 mA with cable length of 2 m)
Insulation resistance 50 M min. (at 500 VDC) between current carry parts and case
Dielectric strength 1,000 VAC for 1 min between current carry parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 10 times each in X, Y, and Z directions
Shock resistance Destruction: 1,000 m/s
2
(approx. 100G) for 10 times each in X, Y, and Z directions
Enclosure
IEC IP67
c
o
s
u
e
rating
NEMA 1, 4, 6, 12, 13
Weight 65 g 150 g 220 g
Material
Body Brass
a
e
a
Sensing face PBT
E2E2 E2E2