Cylindrical Inductive Proximity Sensor E2E2 Long Barrel Metal Body Inductive Proximity Sensors in a Wide Range of Configurations Available in prewired or quick-disconnect versions Quick-disconnect versions feature metal connectors for durability Easy-to-see LED indicator Flats for wrench tightening Ideal for a wide variety of applications Ordering Information SENSORS DC 2-wire Models Type Size Sensing Distance Output Configuration Part Number Shielded S e ded M12 3 mm NO (see n
E2E2 E2E2 DC 3-wire/Pre-wired Models Type Size Sensing Distance Output Configuration Part Number Shielded S e ded M12 2 mm NPN NO E2E2-X2C1 NPN NC E2E2-X2C2 PNP NO E2E2-X2B1 PNP NC E2E2-X2B2 NPN NO E2E2-X5C1 NPN NC E2E2-X5C2 PNP NO E2E2-X5B1 PNP NC E2E2-X5B2 NPN NO E2E2-X10C1 NPN NC E2E2-X10C2 PNP NO E2E2-X10B1 PNP NC E2E2-X10B2 NPN NO E2E2-X5MC1 NPN NC E2E2-X5MC2 PNP NO E2E2-X5MB1 PNP NC E2E2-X5MB2 NPN NO E2E2-X10MC1 NPN NC E2E2-X10MC2 PNP NO E2E2-X10MB1 PNP
E2E2 E2E2 AC 2-wire/Pre-wired Models Type Size Sensing Distance Output Configuration Part Number Shielded S e ded M12 2 mm NO E2E2-X2Y1--US NC E2E2-X2Y2--US NO E2E2-X5Y1--US NC E2E2-X5Y2--US NO E2E2-X10Y1--US NC E2E2-X10Y2--US NO E2E2-X5MY1--US NC E2E2-X5MY2--US NO E2E2-X10MY1--US NC E2E2-X10MY2--US NO E2E2-X18MY1--US NC E2E2-X18MY2--US M18 8 Unshielded U s e ded 5 mm M30 10 mm M12 5 mm M18 M30 30 10 mm 18 8 mm AC 2-wire/Connector Models Type Size Sensing Distanc
E2E2 E2E2 Specifications E2E2-X D DC 2-wire Models E2E2-X8MD E2E2-X7D E2E2-X14MD E2E2-X3D Size M12 Type Shielded Unshielded Shielded Unshielded Shielded Unshielded Sensing distance 3 mm (0.12 in) ±10% 8 mm (0.31 in) ±10% 7 mm (0.28 in) ±10% 14 mm (0.55) ±10% 10 mm (0.39) ±10% 20 mm (0.79 in) ±10% Supply voltage (operating voltage range) 12 to 24 VDC, ripple (p-p): 10% max., (10 to 30 VDC) Leakage current 0.8 mA max.
E2E2 E2E2 DC 3-wire Models E2E2-X C /B Size M12 Type Shielded Unshielded Shielded Unshielded Shielded Unshielded Sensing distance 2 mm (0.08 in) ±10% 5 mm (0.20 in) ±10% 5 mm (0.20 in) ±10% 10 mm (0.39 in) ±10% 10 mm (0.39 in) ±10% 18 mm (0.71 in) ±10% Supply voltage (operating voltage range) 12 to 24 VDC, ripple (p-p): 10% max., (10 to 55 VDC) Current consumption 13 mA max.
E2E2 E2E2 AC 2-wire Models E2E2-X Y E2E2-X10MY US Size M12 Type Shielded Unshielded Shielded Unshielded Shielded Unshielded Sensing distance 2 mm (0.08 in) ±10% 5 mm (0.20 in) ±10% 5 mm (0.20 in) ±10% 10 mm (0.39 in) ±10% 10 mm (0.39 in) ±10% 18 mm (0.71 in) ±10% Supply voltage (operating voltage range) (see note 1) 24 to 240 VAC, 50/60 Hz (20 to 264 VAC) Leakage current 1.7 mA max. Sensing object Magnetic metals Setting distance 0 to 1.6 mm (0 to 0.
E2E2 E2E2 Engineering Data OPERATING RANGE (TYPICAL) Shielded Models E2E2-X C /B E2E2-X Y E2E2-X D Sensing distance X (mm) E2E -X10D Sensing distance X (mm) Sensing distance X (mm) E2E -X10 E2E -X7D E2E -X2 E2E -X5 E2E -X3D Y (mm) Y (mm) Unshielded Models Y (mm) E2E2-X MC /B E2E2-X MY Sensing distance X (mm) E2E2-X MD Sensing distance X (mm) Sensing distance X (mm) E2E -X5M E2E -X20MD E2E -X18M
E2E2 E2E2 RESIDUAL OUTPUT VOLTAGE (TYPICAL) Residual output voltage (V) E2E2-X D Load current (mA) E2E2-X Y Residual output voltage Proximity Sensor 24 VAC Residual load voltage Proximity Sensor 100 VAC Residual load voltage Load current (mA) 200 VAC Residual load voltage Load current (mA) SENSING DISTANCE VS.
E2E2 E2E2 Sensing distance (mm) E2E2-X20MD Sensing distance (mm) E2E2-X14MD Sensing distance (mm) E2E2-X8MD Mild steel Stainless steel (SUS304) Brass Aluminum Copper Aluminum Copper Side length of sensing object d (mm) Brass Sensing distance (mm) Stainless steel (SUS304) Stainless steel (SUS304) Brass Aluminum Side length of sensing object d (mm) Brass Aluminum Side length of sensing object d (mm) Sensing distance (mm) Stainless steel (SUS304) Brass Aluminum E2E2-X18MC /B E2E2
E2E2 E2E2 Operation OUTPUT CIRCUITS DC 2-wire Models DC 3-wire Models E2E2-X D 1 E2E2-X C Brown 1 Load +V 100 Ω Brown Load Main circuit Black Main circuit 4 (or 2) Blue 4 (or 2) 0V Blue 3 0V DC 3-wire Models AC 2-wire Models E2E2-X B E2E2-X Y Brown 1 (or 3) Brown 1 +V Load Main circuit Black 4 (or 2) Main circuit Blue 2 (or 4) Load 100 Ω Blue 3 0V OPERATING CHARTS DC 2-wire Models E2E2-X D NO Type Non-sensing zone NC Type Setting position Unstable
E2E2 E2E2 Dimensions Unit: mm (inch) PRE-WIRED MODELS E2E2-X8MD E2E2-X5M E2E2-X3D E2E2-X2 60 (2.36) 55 (2.17) 21 dia. (0.83) 21 dia. (0.83) 60 (2.36) 55 (2.17) 7 (0.28) 9 dia. M12 × 1 Operation indicator Two clamping nut Round vinyl-insulated cable 4 dia. (0.08 dia. x 60) Toothed washer 2/3 cores Standard length: 2 m Operation indicator M12 × 1 Two clamping nut Toothed washer Round vinyl-insulated cable 4 dia. (0.08 dia.
E2E2 E2E2 CONNECTOR MODELS (SHIELDED) CONNECTOR MODELS (UNSHIELDED) E2E2-X2C -M1/B -M1 E2E2-X5MC -M1/B -M1 70 (2.76) 21 dia. (0.83) 17 70 (2.76) 21 dia. (0.83) 55 (2.17) M12 x 1 4 55 (2.17) 7 (0.28) 17 10 9 dia. Operation indicator M12 x 1 10 4 Operation indicator M12 x 1 M12 x 1 Two clamping nut Two clamping nut Toothed washer Toothed washer E2E2-X2Y -M4 E2E2-X5MY -M4 70 (2.76) 21 dia. (0.83) 70 (2.76) 21 dia. (0.83) 17 55 (2.17) 7 (0.
E2E2 E2E2 CONNECTOR MODELS (SHIELDED) CONNECTOR MODELS (UNSHIELDED) E2E2-X10C -M1/B -M1 E2E2-X18MC -M1/B -M1 80 (3.15) 42 dia. (1.65) 36 5 80 (3.15) 42 dia. (1.65) 65 (2.56) 10 65 (2.56) 13 (0.51) 36 5 10 26.8 dia. M12 x 1 M12 x 1 Operation indicator Operation indicator M30 x 1.5 Two clamping nut Toothed washer M30 x 1.5 Two clamping nut Toothed washer E2E2-X10Y -M4 E2E2-X18MY -M4 80 (3.15) 42 dia. (1.65) 36 5 80 (3.15) 42 dia. (1.65) 36 65 (2.
E2E2 E2E2 Installation CONNECTION E2E2-X Y E2E2-X D DC 2-wire Models AC 2-wire Models Brown Brown Load Power supply Power supply Blue Blue Note: Load The load can be connected as shown in the above diagrams.
E2E2 E2E2 E2E2-X Y -M4 AC 2-wire Model Applicable Models Pin Arrangement E2E2-X Y -M4 Load 3 2 AC MOUNTING Do not tighten the nut with excessive force. A washer must be used with the nut. Shielded Model Unshielded Model Part B Part A Note: The table below shows the tightening torques for part A and part B nuts. In the previous examples, the nut is on the sensor head side (part B) and hence the tightening torque for part B applies.
E2E2 E2E2 MUTUAL INTERFERENCE B A When installing two or more Sensors face to face or side by side, ensure that the minimum distances given in the following table are maintained.
E2E2 E2E2 Precautions Cord Tractive Force Do not pull cords with the tractive forces exceeding the following. INSTALLATION Power Reset Time The Proximity Sensor is ready to operate within 100 ms after power is supplied. If power supplies are connected to the Proximity Sensor and load respectively, be sure to supply power to the Proximity Sensor before supplying power to the load. Power OFF The Proximity Sensor may output a pulse signal when it is turned off.
E2E2 E2E2 DC 2--wire Models, continued Refer to the following to calculate the bleeder resistance and the allowable power of the bleeder resistor. R VS/(iR -- iOFF) (kΩ) P > VS2/R (mW) P: The allowable power of the bleeder resistor. (The actual power capacity of the bleeder resistor must be at least a few times as large as the allowable power of the bleeder resistor.) iR: Leakage current of Sensors (mA) iOFF: Release current of load (mA) The following resistors are recommended.
E2E2 E2E2 PRECAUTIONS FOR AC OR DC 2-WIRE PROXIMITY SENSORS IN OPERATION, CONTINUED Model Connection Type AC 2-wire OR (parallel connection) Method Description In principle, more than two Proximity Sensors cannot be connected in parallel. Incorrect A Load Provided that Proximity Sensor A does not operate with Proximity Sensor B simultaneously and there is no need to keep the load operating continuously, the Proximity Sensors can be connected in parallel.
E2E2 E2E2 NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4. OMRON ELECTRONICS, INC. OMRON CANADA, INC. One East Commerce Drive Schaumburg, IL 60173 885 Milner Avenue Scarborough, Ontario M1B 5V8 1-800-55-OMRON 416-286-6465 Cat. No. CEDSAX2 3/97 Specifications subject to change without notice. Printed in U.S.A.