Datasheet

E2E/E2EQ NEXT Series
18
E2E NEXT Series (Standard-distance type)
DC 2-wire
*1. Use the Sensor within the range in which the setting indicator (green LED) is ON (except D2 Models).
*2. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the
standard.
*3. The IP67G is the degree of protection which is defined according to the JIS (Japanese Industrial Standards).
The IP67 indicates the same level of protection as defined by the IEC, and the G indicates that a device has resistance to oil.
*4. The Oil-resistant Component Evaluation Standards are OMRON's own durability evaluation standards.
2-year oil resistance indicates the median value of the product design and the oil-resistance performance criterion result (=Typical value).
The Pre-wired Connector Model verifies 2 years of oil resistance when mating with Round Oil-resistant Connectors XS5 NEXT series correctly.
The degree of protection is not satisfied with the part where cable wires are uncovered for the Pre-wired Models.
Size M8 M12 M18
Shielded Shielded
Item Model E2E-X1R5D@ E2E-X2R5D@ E2E-X5D@
Sensing distance 1.5 mm ±10% 2.5 mm ±10% 5 mm ±10%
Setting distance *1 0 to 1.2 mm 0 to 2 mm 0 to 4 mm
Differential travel 10% max. of sensing distance
Detectable object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 19.)
Standard sensing object Iron, 10 × 10 × 1 mm Iron, 12 × 12 × 1 mm Iron, 18 × 18 × 1 mm
Response frequency *2 250 Hz 250 Hz 250 Hz
Power supply voltage 10 to 30 VDC, (including 10% ripple (p-p))
Leakage current 0.8 mA max.
Control output
Load current 3 to 100 mA
Residual voltage
Polarity: 3 V max. (Load current: 100 mA, Cable length: 2 m)
No polarity: 5 V max. (Load current: 100 mA, Cable length: 2 m)
Indicator
D1 Models: Operation indicator (orange), Setting indicator (green)
D2 Models: Operation indicator (orange)
Operation mode
D1 Models: NO
D2 Models: NC
Protection circuits Surge suppressor, Load short-circuit protection
Ambient temperature range Operating: -25 to 70°C, Storage: -40 to 85°C (with no icing or condensation)
Ambient humidity range Operating and Storage: 35% to 95% (with no condensation)
Temperature influence ±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C
Voltage influence ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range
Insulation resistance 50 M min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case
Vibration resistance (destruction) 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance (destruction)
500 m/s
2
10 times each in X, Y, and Z
directions
1,000 m/s
2
10 times each in X, Y, and Z directions
Degree of protection
Pre-wired Models/Pre-wired Connector Models: IP67 (IEC 60529), IP67G
*3 (JIS C 0920 Annex 1) Passed OMRON's
Oil-resistant Component Evaluation Standards
*4 (Cutting oil type: specified in JIS K 2241:2000, Temperature: 35°C
max.) and IEC 60529 (old standard: DIN 40050 PART9) IP69K
Connecting method Pre-wired Models (Standard cable length: 2 m) and Pre-wired Connector Models (Standard cable length: 0.3 m)
Weight
(packed state)
Pre-wired Models Approx. 60 g Approx. 70 g Approx. 130 g
Pre-wired Connector
Models
Approx. 30 g Approx. 40 g Approx. 70 g
Materials
Case Stainless steel (SUS303) Nickel-plated brass
Sensing surface Polybutylene terephthalate (PBT)
Clamping nuts Nickel-plated brass
Toothed washer Zinc-plated iron
Cable Vinyl chloride (PVC)
Accessories Instruction manual, Clamping nuts, Toothed washer
Refer to the timing charts under I/O Circuit Diagrams on page 22 for details.