Datasheet

E2E/E2EQ NEXT Series
25
XS5 NEXT Series XS5E2E/E2EQ NEXT Series
Dimensions
Sensors
E2E NEXT Series (Long-distance type) DC 2-wire
(Unit: mm)
Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified.
Pre-wired Models
Shielded
Pre-wired Models
Unshielded
15 dia.
13
M8 × P1
Toothed washer
Two clamping nuts
Indicators
*
4-dia. vinyl-insulated round cable with
2 conductors (Conductor cross section:
AWG24, Insulator diameter: 1.05 mm),
Standard length: 2 m
4
26
10
4.4
33.4
4
* D1 Models: Operation indicator (Orange), Setting indicator (Green)
D2 Models: Operation indicator (Orange)
1
E2E-X3D@8
8
20
33.4
4.4
3
6
13
Indicators
*
Two clamping nuts
Toothed washer
M8 × P1
15 dia.
4-dia. vinyl-insulated round cable with
2 conductors (Conductor cross section:
AWG24, Insulator diameter: 1.05 mm),
Standard length: 2 m
* D1 Models: Operation indicator (Orange), Setting indicator (Green)
D2 Models: Operation indicator (Orange)
E2E-X6MD@8
E2E-X7D@12
12
3.7
4
5.5
1
Indicators *
Two clamping nuts
Toothed washer
21 dia.
17
47.1
33
43.4
M12 × P1
4-dia. vinyl-insulated round cable with
2 conductors (Conductor cross section:
AWG24, Insulator diameter: 1.05 mm),
Standard length: 2 m
* D1 Models: Operation indicator (Orange), Setting indicator (Green)
D2 Models: Operation indicator (Orange)
E2E-X10MD@12
17
M12 × P1
47.1
10
33
4
43.4
3.7
7
26
4-dia. vinyl-insulated round cable with
2 conductors (Conductor cross section:
AWG24, Insulator diameter: 1.05 mm),
Standard length: 2 m
Toothed washer
Two clamping nuts
Indicators
*
21 dia.
* D1 Models: Operation indicator (Orange), Setting indicator (Green)
D2 Models: Operation indicator (Orange)
24
M18 × P1
12
38
46.8
8.5
55.3
4
6
Indicators
*
Two clamping nuts
Toothed washer
29 dia.
* D1 Models: Operation indicator (Orange), Setting indicator (Green)
D2 Models: Operation indicator (Orange)
6-dia. vinyl-insulated round cable
with 2 conductors (Conductor cross
section: AWG20, Insulator diameter:
1.5 mm), Standard length: 2 m
1
E2E-X11D@18
E2E-X20MD@L18
24
60
4
68.8
8.5
77.3
13
47
12
M18 × P1
Two clamping nuts
Toothed washer
Indicators
*
* D1 Models: Operation indicator (Orange), Setting indicator (Green)
D2 Models: Operation indicator (Orange)
29 dia.
6-dia. vinyl-insulated round cable
with 2 conductors (Conductor cross
section: AWG20, Insulator diameter:
1.5 mm), Standard length: 2 m
E2E-X20D@30
36
43
12
8.3
52
60.3
4
7
M30 × P1.5
* D1 Models: Operation indicator (Orange), Setting indicator (Green)
D2 Models: Operation indicator (Orange)
Indicators
*
Two clamping nuts
Toothed washer
42 dia.
6-dia. vinyl-insulated round cable
with 2 conductors (Conductor cross
section: AWG20, Insulator diameter:
1.5 mm), Standard length: 2 m
1
E2E-X40MD@L30
36
5
50
10
8.3
74
82.3
65
15
* D1 Models: Operation indicator (Orange), Setting indicator (Green)
D2 Models: Operation indicator (Orange)
Indicators
*
Two clamping nuts
Toothed washer
42 dia.
M30 × P1.5
6-dia. vinyl-insulated round cable
with 2 conductors (Conductor cross
section: AWG20, Insulator diameter:
1.5 mm), Standard length: 2 m
Mounting Hole Dimensions
Dimensions F (mm)
M8 8.5 dia.
M12 12.5 dia.
M18 18.5 dia.
M30 30.5 dia.
F
+0.5
0
+0.5
0
+0.5
0
+0.5
0
Angle R of the Bending Wire
Dimensions
R
(mm)
M8
12
M12
M18
18
M30
10 mm
R
Wire pullout position
Dimensions
Sc
(mm)
M8
- (0)
M12
M18
2.5
M30
Sc