Datasheet
E2E
9
Unshielded DC 2-Wire Models with Self-diagnosis Output [Refer to Dimensions on page 27.]
*1. Models with different frequencies are also available. The model number is E2E-X @MD15S (example: E2E-X8MD15S 2M).
*2. Refer to page 22 for details.
Connector Pin Assignments of DC 2-Wire Models
• The connector pin assignments of each New E2E DC 2-Wire Model
conform to IEC 947-5-2 Table III. (Only DC 2-Wire Models have
been changed in comparison to the previous models.)
• The following models with conventional connector pin assignments
are available as well. (Only NO Models can be used.)
The cable at the right should also be used if the XW3A-P@45-G11
Connector Junction Box is already being used.
Models with conventional connector pin assignments are available as well.
* Refer to page 22 for details.
2-Wire Models
Appear-
ance
Sensing distance
Connection
method
Cable
specifications
Polar-
ity
Opera-
tion
mode
Pin
arrangement
Applicable
connector
code *2
Model
M12
Pre-wired Mod-
els (2 m)
PVC (oil-resistant)
Yes
NO
--- --- E2E-X8MD1S 2M *1
M12 Connector
Models
---
2: +V and diagnostic output
3: 0 V
4: +V and control output
D E2E-X8MD1S-M1
M18
Pre-wired Mod-
els (2 m)
PVC (oil-resistant)
--- --- E2E-X14MD1S 2M *1
M12 Connector
Models
---
2: +V and diagnostic output
3: 0 V
4: +V and control output
D E2E-X14MD1S-M1
M30
Pre-wired Mod-
els (2 m)
PVC (oil-resistant)
--- --- E2E-X20MD1S 2M *1
M12 Connector
Models
---
2: +V and diagnostic output
3: 0 V
4: +V and control output
D E2E-X20MD1S-M1
8 mm
14 mm
20 mm
Cable length Model
500 mm XS2W-D421-BY1
3
4
4
1
Internal Wiring
(Proximity Sensor end) (Wired end)
Appearance
Model
NO Applicable connector code * NC Applicable connector code *
M8 E2E-X2D1-M1 C E2E-X2D2-M1 D
M12 E2E-X3D1-M1 C E2E-X3D2-M1 D
M18 E2E-X7D1-M1 C E2E-X7D2-M1 D
M30 E2E-X10D1-M1 C E2E-X10D2-M1 D
M8 E2E-X4MD1-M1 C E2E-X4MD2-M1 D
M12 E2E-X8MD1-M1 C E2E-X8MD2-M1 D
M18 E2E-X14MD1-M1 C E2E-X14MD2-M1 D
M30 E2E-X20MD1-M1 C E2E-X20MD2-M1 D
Shielded
Unshielded