Datasheet

E2E
9
Unshielded DC 2-Wire Models with Self-diagnosis Output [Refer to Dimensions on page 27.]
*1. Models with different frequencies are also available. The model number is E2E-X @MD15S (example: E2E-X8MD15S 2M).
*2. Refer to page 22 for details.
Connector Pin Assignments of DC 2-Wire Models
The connector pin assignments of each New E2E DC 2-Wire Model
conform to IEC 947-5-2 Table III. (Only DC 2-Wire Models have
been changed in comparison to the previous models.)
The following models with conventional connector pin assignments
are available as well. (Only NO Models can be used.)
The cable at the right should also be used if the XW3A-P@45-G11
Connector Junction Box is already being used.
Models with conventional connector pin assignments are available as well.
* Refer to page 22 for details.
2-Wire Models
Appear-
ance
Sensing distance
Connection
method
Cable
specifications
Polar-
ity
Opera-
tion
mode
Pin
arrangement
Applicable
connector
code *2
Model
M12
Pre-wired Mod-
els (2 m)
PVC (oil-resistant)
Yes
NO
--- --- E2E-X8MD1S 2M *1
M12 Connector
Models
---
2: +V and diagnostic output
3: 0 V
4: +V and control output
D E2E-X8MD1S-M1
M18
Pre-wired Mod-
els (2 m)
PVC (oil-resistant)
--- --- E2E-X14MD1S 2M *1
M12 Connector
Models
---
2: +V and diagnostic output
3: 0 V
4: +V and control output
D E2E-X14MD1S-M1
M30
Pre-wired Mod-
els (2 m)
PVC (oil-resistant)
--- --- E2E-X20MD1S 2M *1
M12 Connector
Models
---
2: +V and diagnostic output
3: 0 V
4: +V and control output
D E2E-X20MD1S-M1
8 mm
14 mm
20 mm
Cable length Model
500 mm XS2W-D421-BY1
3
4
4
1
Internal Wiring
(Proximity Sensor end) (Wired end)
Appearance
Model
NO Applicable connector code * NC Applicable connector code *
M8 E2E-X2D1-M1 C E2E-X2D2-M1 D
M12 E2E-X3D1-M1 C E2E-X3D2-M1 D
M18 E2E-X7D1-M1 C E2E-X7D2-M1 D
M30 E2E-X10D1-M1 C E2E-X10D2-M1 D
M8 E2E-X4MD1-M1 C E2E-X4MD2-M1 D
M12 E2E-X8MD1-M1 C E2E-X8MD2-M1 D
M18 E2E-X14MD1-M1 C E2E-X14MD2-M1 D
M30 E2E-X20MD1-M1 C E2E-X20MD2-M1 D
Shielded