Datasheet
21
E2E
DC 3-Wire Models
AC 2-Wire Models
AC/DC 2-Wire Models
Operation
mode
Output
specifica-
tions
Model Timing Chart Output circuit
NO
NPN output
E2E-X@E@
E2E-X@E@-M1
E2E-X@E@-M3
NC
NO
PNP output
E2E-X@F@
E2E-X@F@-M1
E2E-X@F@-M3
NC
Operation
mode
Model Timing Chart Output circuit
NO
E2E-X@Y@
E2E-X@Y@-M1
NC
Operation
mode
Model Timing Chart Output circuit
NO E2E-X@T1
Present
Not present
ON
OFF
ON
OFF
High
Low
Operation
indicator (red)
Sensing
object
Control output
(between brown
and black leads)
Output voltage
(between black
and blue leads)
+V
Tr
0 V
100 Ω
3
4
1
Load
Brown
Black
*Constant current output is 1.5 to 3 mA.
Blue
Constant
current*
Proximity
Sensor
main
circuit
Note: For Connector Models, the
connection between pins 1, 4 and 3
uses an NO contact, and the
connection between pins 1, 2 and 3
uses an NC contact.
2
Present
Not present
ON
OFF
ON
OFF
High
Low
Operation indicator
(red)
Sensing object
Control output
(between brown and
black leads)
Output voltage
(between black and
blue leads)
Present
Not present
ON
OFF
ON
OFF
High
Low
Operation indicator
(red)
Sensing object
Control output
(Between blue and
black leads)
Output voltage
(between brown
and black leads)
100 Ω
Tr
+V
*
Load
Brown
Black
*When a transistor is connected
Blue
Proximity
Sensor
main
circuit
Note: For Connector Models, the
connection between pins 1, 4 and 3
uses an NO contact, and the
connection between pins 1, 2 and 3
uses an NC contact.
0 V
3
4
1
2
Present
Not present
ON
OFF
ON
OFF
High
Low
Operation indicator
(red)
Sensing object
Control output
(Between blue and
black leads)
Output voltage
(between brown
and black leads)
Present
Not present
ON
OFF
Operate
Reset
Operation
indicator (red)
Sensing
object
Control output
Load
Brown 3 (or 1)
Blue 4 (or 2)
Proximity
Sensor
main
circuit
Note: For Connector Models, the connection
between pins 3 and 4 uses an NO
contact, and the connection between
pins 1 and 2 uses an NC contact.
Present
Not present
ON
OFF
Operate
Reset
Operation
indicator (red)
Sensing
object
Control
output
80100 0
(%)
Sensing
object
Rated
sensing
distance
Stable sensing area
Non-sensing
area
Unstable
sensing
area
Set position
Proximity Sensor
ON
OFF
ON
OFF
ON
OFF
Setting indicator
(green)
Operation
indicator (red)
Control output
24 to 240 VDC
48 to 240 VAC
Load
Brown
Blue
Proximity
Sensor
main
circuit
Power
supply
Note: The load can be connected to either the +V or
0 V side.
There is no need to be concerned about the